  1. mccullnc1

    Panasonic KXTEA308 v3 - PSTN ring delay on SLTs

    Hi! So to prove if a problem, set all to no ring bar one SLT and then see if delay, then one SLT and one PT. Ill give that a try....Regards Neville p.s. Installed 2no. KXTT7730 and 3no. SLTs / POTs.
  2. mccullnc1

    Panasonic KXTEA308 v3 - PSTN ring delay on SLTs

    Hi! Compared to PT phones, there is a 2-3second delay before the handset rings on i/c pstn calls. Am I missing asetting? UK spec - 8no. PT / SLT ports. Many thanks
  3. mccullnc1

    KX-TA308 programing mode

    The system settings can be programed by using a proprietary telephone (PT) with a display, e.g. the KX-T7730. An authorised administrator connected to extension jack 01 can access system programming. Press [program] [#] [numeric password] then the numeric [program code]. All this info in the...
  4. mccullnc1

    Panasonic KXTEA308 Firmware

    Many thanks, all resolved! :)
  5. mccullnc1

    Panasonic KXTEA308 Firmware

    Hi! Yes, in UK. Regards Neville
  6. mccullnc1

    Panasonic KXTEA308 Firmware

    Hi! Yes you can program thro' the PT phone, but it is a real pain compared to the PC I/F. Especially changing text strings. So would like to source the v1 Maintenace Console. Regards Neville
  7. mccullnc1

    Panasonic KXTEA308 Firmware

    Hi! Yes, have two versions of v2 and one on v3. No luck with either. Did find an answer, can do this thro' PT, prog 998, and then flip-flop [select] button. Meet your first V1, v1.0.6. Now to find a compatible Maintenance Console version.
  8. mccullnc1

    Panasonic KXTEA308 Firmware

    Hi! How do you check which firmware is installed so you can use the right Maintenace Console software? Can it be displayed on a PT, if so how?....Neville
  9. mccullnc1

    Analog TN2793 wire schema to patch panel

    In addition, I assume you are using the amphonal cable and cutting the plug off one end.
  10. mccullnc1

    Analog TN2793 wire schema to patch panel

    Hi, Do you know the CW1308 cable colour code? A-wire in 5 pair units Wh - Rd - Yw - Bk - Vi B-wire Bl , Or, Gn, Bn, Sl. The patch panel uses the 'blues' i.e. 4+5, 5 being the A-wire. Outlet 1 = Wh/Bl on 5 and Bl/Wh on 4. thro' to outlet 24 Vi/Bn on 5 and Bn/Vi on 4. Vi/Sl pair is spare.
  11. mccullnc1

    Changing a ACD Handset from M2216 to a M3905

    Hi! Is it as simple as changing the type in LD11 or is there other problems associated with changing the phone over?
  12. mccullnc1

    Virtual Office - step-by-step guide needed

    Hi, I'm difficulty in setting Virtual Office up using M3904 handsets, M1 X11r25.15 I must be missing a step or CLS somewhere. LD 97 to create the phantom loop; LD 57 to create or amend FFC; LD11 to create the Host and Virtual TN, 3904H or 3904V; LD 15 for the default Station control Password...