Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. chicagotechsolutions

    No Caller ID inbound from Cisco SPA112 ATA

    Hi All! So I've got my lab set up and all the phones configured and I'm looking to add some analog lines to it. In my case the cheapest way is to add analog trunks via an ATA (registered with Voip.MS) and then have the analog ports on the ATA connect to the analog ports of my SG60/12 (direct...
  2. chicagotechsolutions

    Shared DNs and Overlay DN

    I am in the process of designing a small CME system for my home so that I can experiment a little with it. Where I work we have a CCME set up with Shared DNs and they work well since there are four lines going in and each rings on a respective shared DN resulting in a key system effect. This...
  3. chicagotechsolutions

    high end audio install

    Well, the problem is that all of the A&F installs are subcontracted by a music production company called PlayNetwork and i have no idea who PlayNetwork subcontracts for these installs.
  4. chicagotechsolutions

    high end audio install

    Just out of interest, has anyone here ever done an Abercrombie & Fitch audio install? What do they tap their speakers at? The music in there is really loud and the quality is very good. I know they use Tannoy i5taw speakers, but does anyone know what kind of amps they use? The reason why I ask...
  5. chicagotechsolutions

    quick SMDR and Admin question

    Yeah, im interested too. I'll definately give that a try as well, I measured the distance to the office, its about 60 feet, so hopefully thats not too far over the limit and admin might work.
  6. chicagotechsolutions

    Wiring Question

    yup, 2 pair in the positions 3,4,5,6 on an 8 position jack, or pairs 2,3,4,5 on a 6 position jack.
  7. chicagotechsolutions

    quick SMDR and Admin question

    Skip 555, that's exactly what I was planning to do, we have two ethernet drops to each office, so for mine I'll use one of them for SMDR. Should work great, I'm installing this early next week. Ill let you guys know how it goes. Thanks again for all your help.
  8. chicagotechsolutions

    quick SMDR and Admin question

    Thanks for your replies. This is for a residential application (my house)so 50 feet should be plenty. Skip555, wow, I never realized it would go that far for SMDR, I guess admin wouldn't go as far because its not only receiving but also sending. Thanks for your help
  9. chicagotechsolutions

    quick SMDR and Admin question

    I have SMDR and Admin set up fine on my system. Do any of you know if there is a limit as to how long the SMDR and Admin cords can be (if there is any limit)? I'd like to run admin and SMDR cords to my office so that I can view the information and admin the system from my desk, instead of...
  10. chicagotechsolutions

    Paging System Speaker Cable

    Yeah, I agree labeling (I use a thermal label printer) is incredibly helpful when it comes to troubleshooting. I usually label all extension ports and cables in all of my installs (at both ends), so I will do the same with the paging install as well. Thanks again for the advice, db
  11. chicagotechsolutions

    Paging System Speaker Cable

    Thanks again for the recommendations! I found some belden 18AWG shielded twisted pair cable that I think would work well. Barrier strips are a great idea, I completely forgot about them. Thanks
  12. chicagotechsolutions

    Paging System Speaker Cable

    Hi, I was reading some of the posts in this forum. From what I have read I am aware that for a 70V paging installation it 20 gauge sheilded cable is recommended. Does anyone know where exactly I can find some of this cable? If I did a home-run type installation with several loops running to...
  13. chicagotechsolutions

    definity licensing

    Please bear with me, I usually admin partner systems. I was wondering about how definity liscencing works. I have read in various posts that definity needs to be licenced, and certain features must be "activated". I'm not planning on doing this, but if I buy a brand new TN798B circuit pack from...
  14. chicagotechsolutions

    ACS R7 Call Log

    I am about to receive my Partner Messaging PC card. Before I install it i had one more question. The partner phones, as far as I can tell, only log calls if the call goes unanswered, or it also logs the call on the phone that it was answered on. Of course, the Log All calls works, but only on...
  15. chicagotechsolutions

    Partner Ethernet Port Future Use

    I just bought an ACS R7. AVAYA says that the ethernet port is for future use. Just out of curiosity, does anyone know what it might be used for? Admin via LAN perhaps? Will Partner ACS ever support IP sets? I've read about rumors that say Partner might become a 2 cab system (on this website)...
  16. chicagotechsolutions

    Partner PC card messaging transfer

    Hi, I just had a quick question, can partner PC card messaging tansfer a caller from AA directly to a users mailbox. Heres the scenario: I have 4 family memebers, when a call rings thru, all house phones ring simultaneously. After 4 rings the AA picks up and asks the caller to select who they...
  17. chicagotechsolutions

    fxs config

    using h323 ato control the vg200
  18. chicagotechsolutions

    fxs config

    I was interested if anyone had any information on how to configure 2 fxs ports to work as regular analog phone extensions with my cisco callmanager (the fxs card is plugged into the nm-2v in my vg200). What does the config look like for the fxs ports? What kind of configuration do I have to do...

Part and Inventory Search

Back
Top