    DTA0019 and Frame Losses on PRI service

    Got an update from the Telco, looks like the UMC carrier cabinet they are served by is oversubscribed and thus many customers have been affected by momentary outages etc similar to ours but not as severe. It amazes me how little information flows down to the people that deal with the problems on...
  2. rheusdens

    DTA0019 and Frame Losses on PRI service

    Yes I have tested it using that method. I changed all the cable pairs to the Demarc point and looped back to me and I did get the rls wrong mode message. Overnight there were no losses of frames, no yellow alarms, the PRI is running clean thus far. Only one blip yesterday.. I will see how it...
  3. rheusdens

    DTA0019 and Frame Losses on PRI service

    According to the Telco, they replaced the card in the UMC at the request of the customer. Now the problem has evolved a bit, there are fewer frame losses but now the pri just goes into yellow alarm, drops and then re-establishes. This repeated last night about 5 times. The slip-d and slip-r...
  4. rheusdens

    DTA0019 and Frame Losses on PRI service

    Pcat.. I would tend to agree if the service was net new.. however, the system has been in and working for almost 2 years with no issues other than this one to date.
  5. rheusdens

    DTA0019 and Frame Losses on PRI service

    More monitoring.. watched the PRI loop take a complete dive right at about 2pm, loss of frame caused the PRI loop to reboot, slipd counter jumped up to 17, and then the frame losses went crazy right after that. The counter went up from 9 to 34 in a matter of minutes. I am wondering if rebooting...
  6. rheusdens

    DTA0019 and Frame Losses on PRI service

    Still loosing frames, 9 so far today an counting and thats with little to no traffic on the loop.
  7. rheusdens

    Adding more Virtual TN's to UCM / Element Manager

    You may have to provision another superloop in LD 97 if you are all out of TN's in your superloop. Check licensing under LD 22, prt SLT make sure you are not out of IP licenses. If you have spare cards in your superloop, then just provision a new IP phone on the first unit and then the other 31...
  8. rheusdens

    NTDK15AB -Option 11C power

    I personally think it came down to economics and that they did not want field tech's removing the PCB's from the system. I have had to do the same thing you did, buy a whole chassis, remove the PS and throw the case away. It is a wastefull way to do things.
  9. rheusdens

    DTA0019 and Frame Losses on PRI service

    The customer forced the telco to replace the card yesterday, so far since they have done that there has only been on frame loss since last night. I will continue to monitor it and keep everyone up to date.
  10. rheusdens

    DTA0019 and Frame Losses on PRI service

    The loopback might prove the card is ok, but you need voice traffic on the pri span to cause frame loss. The pri looks fine as long as there are no B channels in use, once the BCH's start being used up, then the frame losses really start then the card resets the loop.
  11. rheusdens

    DTA0019 and Frame Losses on PRI service

    Yes the tracking is locked to the the TMDI card and is sync'd properly to the CO. I don't have any slips, just losses of frames.
  12. rheusdens

    DTA0019 and Frame Losses on PRI service

    I have a pri from the telco that is not slipping but about 3 weeks ago the PRI loop started to experience frame losses, no slips etc but frame losses just like this person's thread thread798-1564761 . My system is a CSE 6.0 system with one PRI but exact same symptoms. I have changed out the...
  13. rheusdens

    BCM 5.0 and H323 Interop with CSE/NRS 6.0

    This system is on a flat network, we are not routing anything because this is a lab environment.
  14. rheusdens

    Replacing a 3.6 hard drive with a 3.7

    You will loose all your voicemail etc and you will have to rebuild anything thats based on HD storage such as IP sets, networking etc. Backups from one version can't be restored to another but the MSC card data will migrate accordingly.
  15. rheusdens

    BCM 5.0 and H323 Interop with CSE/NRS 6.0

    I have a BCM 50 5.0 machine and I am trying to get it to work with my 6.0 CSE. The CSE 6.0 has nothing BUT 1140 ip sets on it, the BCM 50 5.0 has a mix of sets. When we place a call from the CSE to the BCM 5.0, the phone rings and you can answer the call, voice path works. When you call from the...
  16. rheusdens

    Patching issue 400 rel 4

    I have had this happen before. You should patch the system first, then restore the backup. The problem is that the data you restored is based on a newer core release than the old hard drive so now it can't load patches to compare data. I would take out the old data and re-init the whole machine...
  17. rheusdens

    1140/1120 sets and VGMC Card

    Thanks for all the responses.. now that normal operation is confirmed.
  18. rheusdens

    1140/1120 sets and VGMC Card

    No, everything gets transmitted but when you look at the inventory of the card, the firwmare for the 11XX sets is absent. We have no failures of any kind making this look like design intent.
  19. rheusdens

    1140/1120 sets and VGMC Card

    Yes, that part I understand. What I am asking is that there is no firmware for the 11XX sets on the VGMC, we try to transmitt this and it does not go in. Is it necessary that it is there in the even the SS fails and the sets register to the VGMC
  20. rheusdens

    1140/1120 sets and VGMC Card

    We have a customer on 4.5 with 11XX series sets, but when you look at the VGMC card, the firmware does not appear to be on the card iteself. When you transmitt this information from the SS itself via Maintainance, the firmware does not appear to go on the card. Since the card is only for TPS if...