Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. robsod

    Problem with sending message from OWS

    Not a singel clue ?
  2. robsod

    Problem with sending message from OWS

    Hi, In the OWS theres a function to send mail directly to a user. This is working fine for all my users except one. I checked the mail adress in DMG and its correct, i even changed it to a secondary but i didnt help ? Anyone seen this problem before ? Thx Robsod
  3. robsod

    Centralized OWS

    If i have 2 stand alone sites of MD110 only with a H.323 connection between dem for LCR = no GroupSwitch. Is it possible to route all incoming calls on both sites to a OWS number on 1 one the sites. Instead of having a OWS on both sites ? Or must i use a Group Switch for this ?
  4. robsod

    ECA logon takes forever

    Has anyone had the same problem when login on to ECA that i could take up to several minutes before the user is logged on and can preform things like diversions etc ?
  5. robsod

    IP extensions in BC11SP10

    Q: Am i able to use ELU32 boards in BC11SP10 or do i need at least BC11SP13 ? I know that BC12 is recommended for use of IP extensions but i wonder if its possible to try it out on a BC11SP10 system...
  6. robsod

    NIU half or full duplex ?

    With other words it's 10Mbit half duplex by default ? And i cant change it to full duplex ? If i can change it with wich command can i see the settings of the port ?
  7. robsod

    NIU half or full duplex ?

    Hi all, Can i set h/f or duplex on the NIU cards ethernet port ? Is it by deafault half ? Or is it any kind of "auto-negotiation" here ?
  8. robsod

    ALink killed service ?

    Has anyone seen this before ? - Killed Service Busy Timer for 2255 Is it possible to say what has happend and why ? If im correct its becouse of a "divertCall" try. Found it in the part of trace below... InvokeId: 111 value AnswerCallResult ::= noData : NULL <Success> Tue Feb 28 15:25:11.687...
  9. robsod

    Starting CCM services again

    lol After some research i found out that the Agent button is not availible if "Agent privacy" is activated in CM.
  10. robsod

    Ericsson ClockSync

    Is it harmless to turn this off ? What is it good for ?
  11. robsod

    Starting CCM services again

    On a windows NT system the services will not start automatically at least not in my version :) Another question, when i start a Information manager i logges on fine but the button to se information about members from ACD group i grayed out = not availible ? So i cant see any info about these...
  12. robsod

    Starting CCM services again

    If i stop all the CCM services in wich order should they be started again ? Any specifik order or is it just from the top ? If the event services is stopped are is the CCM server still registring call information for all ther reports ?
  13. robsod

    DTMF &quot;dddd&quot; at internal calls

    Yes i even recorded the tones and see them in a spectrum at my computer. I got the system requirments for number of TMU boards from a diffrent source. I know its a firmware upgrade, but i want to know what stuff got corrected in the later (R3D. Maybe the d's got corrected.... FYI to answer my...
  14. robsod

    DTMF &quot;dddd&quot; at internal calls

    me again *lol* Does anyone know the differense between revision status R3A and R3D, whats the latest released revision ?
  15. robsod

    DTMF &quot;dddd&quot; at internal calls

    Additional question, do i really need 5 TMU cards in a 2LIM system, we dont use music on hold. To me it's seems like overkill. Is there any table showing how many i need, or any eqvation ? I'd rather take one out and put as a spare/reserv + have more free timeslots in the LIM.
  16. robsod

    DTMF &quot;dddd&quot; at internal calls

    There are 56 Analoge lines from the MD connected to the IVR. This is the only direct way the MD and IVR are connected. "d" with this i mean that instead of digits i get 4 letters [d] sent :) I'll start with checking if my TMU card is allright then.
  17. robsod

    DTMF &quot;dddd&quot; at internal calls

    So not even a singel hint to a solution of this problem ? Which card in the MD is generating DTMF tones ?
  18. robsod

    DTMF &quot;dddd&quot; at internal calls

    When im dialling an internal number to a IVR application and sends DTMF tones the PBX MD110 sends "dddd" before all the digits... Does anyone know why, and how i get rid of them ? If i make an external call there wont be any d's sent. I have the optinon "press 9" to send DTMF digits. Thx in...
  19. robsod

    Operator console doesn't ring

    Seen the same problem in BC11SP10 systems... Could someone explain whats wrong and how i fix it. When it happens OPTSP; says that the number is "Busy" and "Absent" like its a call stuck on it. Tried RFPUI:UNIT=DOM/DOR is that the best way to go around it ??? Any more solutions ?
  20. robsod

    Route between BC11 and BC12

    I havent seen the cabling on the slave side myself, but how many ways is it possible to connect the cable ?

Part and Inventory Search

Back
Top