  1. marktutt

    Employee Discounts Limits per day

    That would require a SIM talking to a server based back end storage system to track the discounts on a daily basis. Not something you can program in with the vanilla system. Mark Tutt Ramblings of a POS Consultant
  2. marktutt

    Employee Discounts Limits per day

    What POS system?
  3. marktutt

    Micros 3700 and EM Totals

    For organizations with the need, they're working with consultants to develop their own data warehouses. However it's a never ending commitment, as every new version of the POS requires accomodating the corresponding changes in the data extraction and posting pieces. Mark Tutt Ramblings of a...
  4. marktutt

    Micros 3700 and EM Totals

    No system on the market will keep 4 years worth of check detail, EM doesn't pull back detail at all, only totals, and MyMicros has a hard limit of 13 months I believe. If you have to have it, you're going to have to go custom, there are about 3 people in the world qualified to do it and it's...
  5. marktutt

    Micros WinStation & SarOps

    Winstation is one of the Ops clients for the Micros 9700 system, and no, it won't work with RES. It's a basically a thin client application working in conjunction with an Ops process running on the server, and architecture that the 3700 does not offer. All RES POS clients are SAR clients, in...
  6. marktutt

    Discount via barcode on Micros 3700?

    Yes, you have to have a SIM script written to do this. Either ask your dealer about it or contact a Micros integration consultant with SIM experience. Mark Tutt Ramblings of a POS Consultant
  7. marktutt

    Micros UWS4's network printing

    There are various problems with doing this, my best advice is don't waste your time trying it. I had a customer go to someone else for a solution because the other party was willing to try this, and the customer came back to me for a working solution 2 weeks ago. Mark Tutt Ramblings of a POS...
  8. marktutt

    MICROS 9700 & Epson IDM TM-88 not printing

    Possibly a blown port on that workstation then. There isn't a printer queue in 9700 that would have survived a reboot, but I've seen weird things happen in the RCC and NetCC connected ones. Mark Tutt Ramblings of a POS Consultant
  9. marktutt

    MICROS 9700 & Epson IDM TM-88 not printing

    Almost too many things to have to check here. If you're using RCC's or NetCC's, have you reset any of these associated with the terminal in question? Have you checked confidence test to see if it is able to see the printer? Do you know how to get into the workstation configuration so you can...
  10. marktutt

    Micros Res 3700 Check Detail Read Failed

    Run these queries in dbisql: select chk_seq from micros.chk_dtl where chk_num = (CHECK NUMBER HERE)and chk_open = 't' Once you have the the check sequence number for the open one run this command: call micros.sp_forcechkclose ( check sequence here); commit; Warning! You can screw up your...
  11. marktutt

    Micros Res 3700 Check Detail Read Failed

    This is a bug in some of the early versions of Micros 3700 4.0. There is no way as an end user to address it. It has been fixed in the latest updates. Mark Tutt Ramblings of a POS Consultant
  12. marktutt

    Looking for Micros training recommendations

    The ODBC driver for the micros apps needs to have TCP/IP checked when logged in via Remote Desktop. Go to Control Panel - Administrative Tools - Data Sources and select the System DSN tab, find the Micros entry. Hit Configure, go to the Network tab and check TCP/IP. You don't need to fill in...

Part and Inventory Search

Back
Top