Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Robones

    Switchboard not forwarding

    Can you build a phantom DID that will connect calls to the other switchboard? Make sure call party disconnect control on the routes is set to either. (NEDC and FEDC) this can prohibit unsupervised trunk to trunk connections.
  2. Robones

    How to add a new DN/rebuild a DN in the switch

    A note on using the MOV command. LD 84/85 does not play well with MOV(ed) TNs. If you must make changes after mov(ing) a set, do a CHG on the TN and return through without making any changes to the set. I had a customer corrupt their system because a new hire did ODAS changes in LD 85 after the...
  3. Robones

    Need help w/setting up Hunt on Busy

    move the dn on key 1 to key 2. change lhk to 2.the gap between scr keys breaks the short hunt. fna and hta will still work for both keys.
  4. Robones

    CDR data from switch not being sent to OTM

    Check the PARM data block in the cfn. CLID is no by default.
  5. Robones

    Incoming digits on a PRI

    Ask the provider of the 800 number, "what CLID are they delivering to you? Can they forward the CLID of the caller?" enable msgi monitoring on the d channel to confirm the numbers with them. Be aware of how much traffic is on that route, moderate call traffic can be too much on a slower tty port.
  6. Robones

    Caller ID - non PRI T1

    I'm new here, but I have had several experiences with this. Back in 1997, a doctor in NY City had his lawyers threaten a Major Hotel (where I worked) with a lawsuit if they did not correct there caller ID. It turns out, AT&T was sending the number out on all calls going out on a plain old T1...

Part and Inventory Search

Back
Top