Can I use a BIS-22D to add the lines
I put x10 in programming mode hit *4 and it's giving me an error
Haven't seen one of these in years and not sure if I need bis-34 set as customer only has bis-22
I have a bcm 400 rel 3.7 connected to a bcm 50 via ip trunks. we have a PRI in the 400 and they want to give a DID to someone working out of the bcm 50. I am unable to enter the received digits i need under the target line for the bcm 50 because they are already in as destination codes for the...
Have just taken over maintenance on a call pilot 201i rel 4.04.04. I can make menu changes in the application builder but when I try and rerecord the prompt it tells me manager is not installed. Any help would be appreciated
Have a weird problem with the fax messaging. Sometimes when faxs come in they go to the mailbox and not into the callpilot desktop application. I'm curious if I need patch or something else is wrong. Does anyone know what the most up to date patch for a rel 3.7 should be. I have access to...
we tried that it didnt make a difference. The solution came from Avaya tier 3 and was as follows Cause :
When we upgrade CM software, system deactivates HTTP/HTTPS RPMs.
Solution:
Download RPM/IP phone firmware bundle files (*.tar) from the support web site and install on the server to...
upgraded a s8300 with g430 rel 5.2.0 to 5.2.1 and now none of the 9620 ip-phones will register. Now all the phones have HTTP: 1-500 on the screen. They are getting an ip-address from the DHCP working off the G430 but will not register. Any help would be appreciated. Waiting patiently for a...
I am in a bind i have a customer that doesnt have a key to phone closet til maintenance guy gets back next week and they want to move 48 more people into the office. I need to get a fiber nam as they have a startalk rel 4.0 now and it is maxed out. Problem is I dont know the release of the...
Have a Bcm 400 rel 3.7 connected to a bcm50 and randomly getting 1 way audio on the sets. It seems to bounce around on the voip trunks the failures are random. Have the june smart update patched on the 50 and the latest feps patch on the 400. Has anyone come across this issue thanks in advance.
Thanks I have it set as follows
bus 2 d32+ - 1 off rest on
bus 3-g4x16 - 6 off rest on
3 will be for trunks 4 for stations
bus 5 gasm1 - 1,5,6 off rest on offset 0
gasm2 - 1,2,5,6 off rest on offset 2
bus 7 dti - 4,6 off rest on
will this work?
Hope someone can help I just cant seem to get my dipswitch settings correct. New install what would be the best configuration for dipswitches with the following mbms
1 dsm32+
1 g4x16
1 dti
2 gasm
any help would be appreciated thanks
Just powered up a bcm 400 rel 4.0 trying to log in with crossover cable via Lan1 10.10.10.1 laptop 10.10.10.2 and I am getting an error mess
x error happened. Error Detail; MofObjectFactory can not be initialized. Error; Error in loadingmof files, java.lang.NullPointerEception
I can get into...
have a bcm 50 just went to install a couple of polycom units. when i just plug in an analog trunk line the polycoms sound fine when i plug in an analog station i get static. Does anyone know of a patch out there for this. thanks in advance.
need to add an expansion cabinet to a bcm 400 rel 3.7. I haven't done this before and having trouble finding any docs on this can someone point me in the right direction?
I have an issue with the mess waiting lights they only stay on for a few seconds. When outlook gets the message using desktop messaging something down the bottom will say send/receive and then the light on the phone goes out. When you log into call pilot to check your mess it will tell you you...