Changed the ASM and it works!
The green lights on the old modules were flashing and the new one came on steady!
Thanks for all the help.
It still says "Enabling" in the status.
Go figure!
Ok, well I re-seated and then changed the FEM and still the same!
The only thing I haven't done is changed the asm module itself.
Will try that when I can get my hands on one.
Any other thoughts?
Ok, that may be it.
To change it,do I just shut down, change the fem and boot back up?
Does the programming reside in the BCM450 or is the fem a smart device that will need to be reprogrammed?
Is there an NT number for the 6 port fem and where would it be?
Would a reseat of the fem maybe...
BCMFiftyfan, I tried everything you said and it still says "enabling".
All the other ports on the FEM are being used by Digital station modules, so I can' change it.
vtphoneguy. yes both are down, and I have tried both individually with different fibre cables.
The second one was not programmed...
Hi
I normally work CS1k but was sent to a BCM450.
It has a Fiber expansion card in slot 3 of the main unit. (No expmansion)
There are 5 digital SM and 2 ASM. The 2 ASM are connected to port 6 on the FEM
The fiber from port 6 goes to the first ASM and then it is daisy chained to the second...
Hi
I normally work CS1k but was sent to a BCM450.
It has a Fiber expansion card in slot 3 of the main unit. (No expmansion)
There are 5 digital SM and 2 ASM. The 2 ASM are connected to port 6 on the FEM
The fiber from port 6 goes to the first ASM and then it is daisy chained to the second...
Just wondering if anyone has been able to get this running on Outlook 2013 and if you have any documentation on how to set it up.
Have not been able to find anything to say it is supported.
Thanks for your help!
I'll take a stab at this!
Instead of using a phantom, program your number on an addon, kba or aom, that is only in programming, on a set that won't disable, say your phone room set.
You should be able to then program your scn keys and xmwk on the sets that need to monitor the mailbox.
Just a...
I have an Octel 250 integrated with an Opt 11 and I only have 3 ports logged in and answering.
I have tried disabling and enabling the ports in M1, but that doesn't log them in.
I seem to remember removing the line card and re-inserting it would reset the ports. I have 2 line cards in it, so...
In LD 95 you can associate a name with a clid table
MEM AVAIL: (U/P): 98454042 USED U P: 4981700 216607 TOT: 103652349
DISK SPACE NEEDED: 304 KBYTES
REQ new
TYPE name
CUST 0
PAGE
DIG
DN
ENTR 0
NAME ABC Company
XPLN 24
DISPLAY_FMT FIRST,LAST
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.