dont forget you need to add your external dest code to the beginning of the TRA if going to a mobile or external landline!!
It's never too late to try something new
Quick update on this guys so this thread can be closed.
we found the problem in the end, turned out to be a dirty fibre on the data network causing packet loss in the frame alignment word. data guys eventually changed to a new pair and hey presto, not had a single wobble since.
thanks for all...
You need to set up your "account" within MDDisktool by adding the login details (MDUSER/PSWD) in the Customer Database section.
on MDDT go to TOOLS-CDA
You have a List of Customers
Next to FILE is Add a new customer and follow the screens to input the required data
If you have already done...
Hi himdp
thanks for your input.
i understand the problem with the synchronisation and there is no way i would aldar an alarm out thats just too dangerous. the problem we have is that we provide multiple dpnss (8 at present) links to this callplus and the 3rd party company seem to be having...
Hi whosrdaddy
prints as follows:-
<cadap;
CALENDAR DATA
IDENTITY=121843-LANCSC-C
VERSION=CXP1010102/4/TSWSP2GB1.14/R3A
11:04:10
WED 09 SEP 2009
END
<scexp;
EXTERNAL SYNC RECEIVING LINES DATA
MASTER LIM STATUS [MASTER SCOPE]
FIRST CHOICE...
We have a persistent issue with ERCO 274 Digital Trunk Clock Malfunction (SLIP) between our MD network and a 3rd party PBX which is a macfarlane Callplus server running on Windows 2003.
We have 8 x DPNSS circuits connected directly from 5 Lims (TLU76 cards) tyo the Callplus Server whuich uses...
Cheers for that /daddy
you are right it is certainly a challenge. we dont have a local external source for that Lim but will endeavour to try your other suggestions.
yes i have heard V4 addresses some of the IP issues and i am certainly putting the argument forward for TSE as the logical...
Hi all
we are currently looking at the options to go to TSE (although there are some who would have us Rip and Replace to the big C) however under increasing pressure we are currently trialling the RADMUX solution to start network convergence and rid ourselves of a hefty networking bill.
we...
there is an easier way! tell your user not to rely on the pbx clock but go and buy a watch! must be cheaper than the amount of engineering time being wasted on this!
It's never too late to try something new
ah! so the ddi calls for the ceo get pushed to solidus which would only act on any cli in the database? if the cli isnt in the database it gets presented to the secretary (boss/secretary setup)as normal?
It's never too late to try something new
think so! i understand the the scripting bit and call deflection criteria within solidus but how do we route the external call based on a single cli presentation? does solidus do that bit? ive been trying nutri etc on the md but nothing seems to work?
or would i have to push all calls through...
thanks whoserdaddy
we have solidus5 and any tips would be appreciated. usually we would just renumber the extension and push the calls to the ddi through to a vm or legal dept however in this case it happens to be the CEO number thats getting the calls so a renumber would be out of the question...
Does anyone know if its possible to capture the inbound caller CLI from the public exchange and redirect the call to a specific extension or dest code regardless of the DDI number the caller has dialled?
e.g i want to capture CLI 01772 123456 who has dialled 01772 987654 (DDI into our system)...
cheers guys
sorry for the delay in getting back. got a successful dump on sat morning.
low traffic plus i did what you suggested whosurdaddy and restarted INR in all Lims.
dstrang1 - i agree its most likely to be a PCM link. unfortunately/fortunately we only have 1 link to lim 40 but i've also...
ok failed again at 13:08
might be getting some clearer indication as to the root of the problem.last 3 DUSYI attempts have all failed at the same point with the following:-
BUFFER TRANSFER ERROR 12:59 22AUG08
FAILED IN LIM040 FOR LIM RELOAD DATA FILE
i've done an immediate Gjtsp on lim40 and...
...VALUE REACHED FOR PCM-LINE
DATE TIME ALP NOIF UNIT EQU INF1 INF2 INF3
22AUG08 09:45:00 10 1 GSP 051-*-**-** 941 599 10
RDATE RTIME
22AUG08 10:00:00
274 DIGITAL TRUNK, CLOCK MALFUNCTION (SLIP)
DATE TIME ALP NOIF UNIT EQU...
Hi all,
got a serious problem at the moment. 56 lim BC13 system with 2 x HDU 7 with split RELs.
Over the last couple of months i have had more dump fails than successes, both on Autodump and manula DUSYI. HDU formats tend to sort the problem for a few days but the main failure is down to buffer...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.