Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Gallian

    Restart reload Requests BC 11

    A problem with LSU yes can be but does anyone agree that the LIMs are trying to restart but cant restart due to the disturbance counters set to 0. I dont have remote LIMs the group switch connections are good but due to some reason the LIMs are trying to restart but cant. One of the reasons...
  2. Gallian

    BC release where calling number is sent to analogue extensions?

    Hi rfpui, I think The license is for the analogue extensions not for CLI feature.Every analogue extension will be able to get CLI if u have the ICAT set so there shouldnt be a license issue tagged to CLI. BR Gallian
  3. Gallian

    Restart reload Requests BC 11

    Hi, I am getting this message very often "Message from the operating system Restart requested LIM initiated" and soon after that I get another request for relaod. Although I am not getting any restarts but soon after I get an alarm stating LIM out of order and relaod failed in lim. Could any one...
  4. Gallian

    Logon problem

    Hi, If it is NIU2 u may need to upgrade the Firmware to R6A. Else resetting the NIU should solve ur problem but do wait till the alarms for device boards faulty or missing is receive then put the board back and wait again for device board activated. After that u should be able to log on. BR Gallian
  5. Gallian

    BC release where calling number is sent to analogue extensions?

    Hi, In BC 11 there was an OMR developed for analogue CLI and it works fine with a patch and a PROM change on the ELU 29 boards. It is defrinitely possible in BC 11.All u need is the patch and the PROM for ur analogue boards. BR Gallian
  6. Gallian

    Caller Id

    Hi FCPLI and soaplover, Does ur replies mean MD110 BC 9 can not have CLI for analogue extensions, as far as FCPLI's FAQ I think its possible can we get some further help on that please. In BC 11 does it have to be thru an OMR doesnt the China version has CLI functionality. My customer wants...
  7. Gallian

    How will the TLU79 work with a FAX server for eFAX

    Hi, I think a TLU76 can also be used in this scenario but we have to use a TLU 79,EDSS1 protocol. A simislar config does also exist some where in EGHAM Surrey UK. Its also using a TLU79. BR Gallian
  8. Gallian

    How will the TLU79 work with a FAX server for eFAX

    Hello Guys, My customer wants to have the efax functionality for there office using TLU79. They want to use Virtual Etensions for this purpose can somebody explain how will it work I have the route parameters but what I dont understand is why do we need to have virtual extensions for this...
  9. Gallian

    WinFIOL 5, hanging up modem connections ?

    Hi, I agree with Vitenari try sending +++ and wait for few seconds u should hear the disconnection and then send ATH0. After ATH0 If ur modem speaker is off u wont hear the disconnection noise. Gallian
  10. Gallian

    Hello guy Has any one a idea how

    Hi, U can look in the SEL parameter of the Route Data the D3 might be what u looking for. You can change it in ROCAC. BR Gallian
  11. Gallian

    ALU29 extensions intermittently not ringing

    Hi, Another way is to check the ELU 29 board, some of the /11 boards do have this problem try replacing the board whos individual does not get the ring. Some times due to external voltages the ELU 29 is unable to get rings. SO try and find out if the ring is not received on one individual or all...
  12. Gallian

    Dumping-buffer transfer error

    Hi, I have also faced this problem a lots of times and sometimes it was days I was unable to take a system dump just because of this error.Even though I used to dump the system at a very low traffic times. Even restarts of the failed PU wouldnt help. I had to reconfigure the whole GSM cables and...
  13. Gallian

    CIL max 59:59

    Hi Bartjo, Well If u have configured form=5 then that means u have a self defined the out put format. U can take CLFOP:FORM=5; and see whats the format like. Offcourse when u will change the FORM =2 that will effect the TABS. So the best thing is to check the CLFOP and see the DATA. BR Gallian
  14. Gallian

    False Busy Trunks on TL 11

    Hi Patcher, The site that has this problem is bit far I am planning a site visit and will used ur SACOS. I do not have modem access to the site. Will get back to you soon. BR Gallian
  15. Gallian

    False Busy Trunks on TL 11

    Ok, We do have a voice mail system and the Incoming calls are routed to the auto attendant,thats DIAVOX everything is then handled and routed by the voice mail system.The DISA has not been initiated. The Problem occurs only with outgoing calls. The alarm 260 is present in the ALLOP when this...
  16. Gallian

    False Busy Trunks on TL 11

    HI, The route data is as follows. ROU TYPE VARC VARI VARO FILTER 1 TL11 H'00000022 H'00000008 H'00000005 NO The CNPIP for TLP 11 is CNPIP:UNIT=TLP11; PROGRAM UNIT INFORMATION PU-NAME PU-NO PRODUCT NUMBER REV PATCH TLP11 H'391...
  17. Gallian

    CIL max 59:59

    Hi, It all depends on how u have defined ur Call Logging. For example if u want the standard format of call loging then u should get the 5 digit call duration as far as I can see ur using FORM=1 that gives u only mmss format. U should define CLOHI as follows and observe the output...
  18. Gallian

    TLU76/4 & ISUP4 signaling

    Hi, The TLU76/4 is a SS7 board used in DRX1 or MD110 with SS7 applications, The AXE and MD are connected thru this board. There are no specific settings for the board. BR ecptfa
  19. Gallian

    False Busy Trunks on TL 11

    CNI Level is 140/R2A. Whats the latest CNI level in BC 10 do u know if there is a patch in any Higher CNI level for this Problem. ecptfa
  20. Gallian

    ISDN30 Board removal

    U might also check with SCEXP if the sync is defined on this position u might have to change the sync with SCEXI. Cuz the 00 port is used for SYNC. ecptfa