Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: chuyjones
  • Order by date
  1. chuyjones

    Octel 350 maximum number of sys dist lists

    I have a specific need for a system distribution list to contain only one network address at a time and I can't use a personal group list.
  2. chuyjones

    Octel 350 maximum number of sys dist lists

    On the Octel 350 is there a limit to the number of type 6 mailboxes (System Distribution List) you can have ? I am assuming that in theory you could have thousands as long as you don't exceed the total mailbox limit of 30,000.
  3. chuyjones

    Migrating Octel 250 to MM R2 help

    The Avaya support web site has some information.
  4. chuyjones

    RTC not Initialised errors?

    Thanks for the information.
  5. chuyjones

    RTC not Initialised errors?

    Had a problem with a 406V2 at 3.0.59. I eventually had to unplug the power supply and wait a few minutes to correct. What is the RTC not intialised error? Here is the output of the System Monitor: 39994mS PRN: RTC not initialised or reading is incorrect , Initialise ... 42334mS PRN: RTC...
  6. chuyjones

    Telnet connection to Octel 250/350 ?

    OK, octelvoice, I don't understand? I have only used a telnet server before.
  7. chuyjones

    Remote station E911

    I know that on my system (406V2 3.0.59 )I had to change the shortcode for 911 to have 911S1234567890 where the 1234567890 was my published local phone number. When I had just the telephone number in the shortcode as 911 I did a test call and the 911 operator informed me that they did not have...
  8. chuyjones

    Octel 250 +5V error ??

    Thanks Ken. There is no red light on the alarm panel, so I will assume everything is OK.
  9. chuyjones

    Octel 250 +5V error ??

    I was having a problem at bootup where one of the fans was dead, so the system would not boot up. I replaced the fan, but I noticed that when I go into System Maintenance I get this display Menu 13 - System Maintenance Review Current Alarm...
  10. chuyjones

    Octel 250 boot up problem

    There was only 1 error in the status log. It was a CD error with offset 47 as 03. That is why I am assuming that the message drive is going bad. The drive configuration line had a D D D . . . T so it saw the 3 drives and the tape drive. After it booted up I did look at the drive status...
  11. chuyjones

    Octel 250 boot up problem

    I had system drive 1 that had been taken out of service due to a failure. I had a spare 2GB drive so I was doing a drive replacement offline. When that procedure was done it rebooted and I got those messages. I am assuming that the message drive is flaky. It still appears to be working, but I...
  12. chuyjones

    Octel 250 boot up problem

    I have an Octel 250 at release 2.0.5. While the system was booting up I got an error on the line for the SCSI Disk drive diagnostic. The information printed out was " *4D/1* *** Got Check condition while doing the check condition cmd the request 2000d to target I.D. 2 ". The next line was...