The two printout commands gives the result, but the printout has changed from the old MX-ONE 5.o printout.
resource_status --equipment --equipment-type EL6 --vacant -l all
resource_status --equipment --equipment-type KL1 --vacant -l all
Maybe you can point me in the correct direction...
How to translate these commands to MX-ONE 7.3 commands (from MX-ONE 5.0)?
Having a MX-ONE 7.3, I should use the following commands:
syedp:lim=all;
syevp:type=kl1;
syevp:type=el6;
I found out that "syedp:lim=all;" could be translated to:
resource_status --lim all --list --equipment
Can you...
Thanks.
We swapped the LSU in LIM=2, here after all faults were gone.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
Hi All
We got this alarm code 101. What should we do?
Seems to me like a power supply since all boards in the magasin are blocked...
<allop;
ALARM LOG
IDENTITY: CUSTOMER
VERSION: CXP1010103/4/TSWSP05/R6A
DATE: 28JUL20 TIME: 12:02:40
CLASS: 4
101 FAULTY CLOCK PROCESSOR
DATE TIME...
To have the callers original A-number presented at the called mobile phone, CLIP-SA first need to be installed at your ISDN connections. You may consult your ISDN provider.
Additional programming may be necessary in your MD110.
///doktor
____________________________________...
We did this by taking a backup of the system, insert this backup in our test lab IPLDK-100 - then make the changes - and finally upload the database in the customers IPLDK-100.
It's a little workaround, but it works well. Pls try and let me know, if it works.
///doktor...
To print AUX number - use EXDDP:DIR=ALL;
EXDDP:DIR=ALL;
EXTENSION DIRECTORY DATA
DIR CUST EQU CAT TYPE ICAT AUX
503 001-0-63-00 - EL6 0000
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
You need to restart both services elm and bluestar licensemanager - to free the licenses.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
You need to restart both services elm and bluestar licensemanager - to free the licenses.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
Try to restart the ELM service. ELM keeps track of the number of logged on agents for InAttend.
Be careful if you use ELM for e.g. Solidus / MiCC.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
Try to restart the ELM service. ELM keeps track of the number of logged on agents for InAttend.
Be careful if you use ELM for e.g. Solidus / MiCC.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
I agrre with ceejay55
Swapping numbers and EQU positions should be avoided.
"how much data corruption do you think will happen ?"
Print all (EXDDP/EXCAP) --> change transmit file with regards to the new numbers --> make a test (delete/change/initiate).
--> Use TextPad or Excel to buold the...
Try it.
80P-C6Db.bin is 80P-3.6Db.bin - since C is the 3.rd letter in the alphabet. Letter means preliminary sw.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
I would make the ADN with ksani (dir, key, odn, adn).
Then the PSTN route with rocai, rodai,roeqi, rodni- where day/nig answering position would be the ADN.
Just an overwiew to start up on.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx
This is the correct capacity:
In ALEX -> BC12SP5 -> FAQ -> Questions and answers -> Capacity description i found this note:
"The total number of extensions (all types) may not exceed 640 per LIM."
It was increased after BC11.
Now with MX-ONE it is even more.
///doktor...
With LDK-100, you can use LDP-7012 and 7024 and other keysets like LKD-30 DS and LDK-8DS.
///doktor
____________________________________
http://www.kandu.dk/spg153996.aspx