What I do is save the desired info (usually a list of mailboxes) as a text file then import that text file into Excel. The steps below assume you already know how to perfom list functions in the MMail and are using ProcommPlus to access the MMail.
1)Just after connecting to MMail via Procomm...
Thanks Scott. I appreciate the response & I agree completely with your advice of pulling cards not in use. I too practice this when possible.
Thaanks Again
Lenny
Lenny Llewellyn
Shentel Telephone Corp.
http://www.shentel.com/
Hello Everyone. I have an Option 61C which I am dropping a couple T-1/PRI circuits, going down to only 1 PRI remaining in the PBX. Of course I currently have a QPC471H CC in both core/net modules which are both cabled to 2 separate NT5D12 DDP cards for primary & secondary clock reference inputs...
I need to write a script in Procomm (Both Windows & DOS Versions) to automate tasks like deleting & entering auth codes. I do this with Nortel PBX's but since NEC has their own proprietary MAT Software, I do not know how to link a script in Procomm to issue commands & data in the NEC MAT. Does...
Thanks everyone for the response. I will check the cabling to the top panel and the col filter. I will try the PE PS Reset but I did power them all down when I replaced the monitor. The only thing I questioned on the dip switch settings was the 1 for PFTU. We do not have PFTU in this PBX but the...
When performing a "STAT XSM" in LD 35 I receive a "PWR013 01 0 0" error on a 2 column M1 Option 61C, Ver 2911 Rls 25. This indicates the communication link between the master system monitor and the slave in col 1 is down. I have replaced the line cord (Nortel refers to this as a Serial Link...
Thanx jbrown1217,
After making this post I found refrence to to this exact same thing on Nortel's website. I opened a tickett with Nortel & the engineer did not make specific reference to this nor did he have me perform the reseat procedure but he did advise upgrading the IODU/C's with our...
I have recently lost access to both floppy disk drives simultaneously on the IODU/C's (NT5D61) in both cores of an Option 61C. I have replaced the floppy disks after formatiing them in DOS & disabled & re-enabled the CMDU's in LD 137. No help. Since this happened to BOTH floppies at the SAME...
I have an Option 61C (2911, Rls. 25)that will not accept the "!" plus the message code input from the crt to show the message desscriptor. I cannot seem to find how to turn this simple feature on. Can anyone help?
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.