  1. Omissam

    Route Pattern MD110 BC9

    Pcpli ok, I tried to do as you say, but I'm not able to configure RODDI because the parameter of DEST is already assigned: example :   LCDDI: TAB = FDT, FRCT = 10, TZONE = 1, PRE = 1,903; LCDDI: TAB = DNT2, INPUT = 178903, TRC = 6, FRCT = 10; RODDI: DEST = 1903 ROU = 2, ADC = 002500000000025000...
  2. Omissam

    Route Pattern MD110 BC9

    Hello fcpli, I do not need the function of time How can I delete it were you referring to this: LCTDP; LEAST COST TIME ZONE DATA DAY TIM1 FDT1 TIM2 FDT2 TIM3 FDT3 M-F 1 SAT 1 SUN 1 END Omissam
  3. Omissam

    Route Pattern MD110 BC9

    Hello fcpli, this is the SACOP: <sacop:unit=lrp6,lim=1,sector=rel,addr=2760; MEMORY CONTENT ON ADDRESS POSITION EXE A ADDRESS 0 1 2 3 4 5 6 7 8 9 A B C D E F ISO 00002760 FF 00 5A 00 13 00 00 00 4A 00 00 00 00 00 00 00 ..Z.....J....... END Thank you
  4. Omissam

    Route Pattern MD110 BC9

    Hello fcpli, the problem is on the table FDT because FRCT not in range and I can not go on [wavey2]
  5. Omissam

    Route Pattern MD110 BC9

    Hi i have this problem: I have to do 160 route patterns by selecting a 6-digit code on the central MD110 BC9 example: 178903 (code route pattern) ...... Bruxelles (site) ........ 3222867004xx (PSTN destination) Configuration performed from me: NANSI:NUMTYP=LC,NUMSE=17...
  6. Omissam

    Problem with external bacbkup

    Think I need a good pair of glasses [bigglasses] [bigglasses] I think I'm getting old sorry[Wavey2]
  7. Omissam

    Problem with external bacbkup

    Hello inlsp05 what should I do? Add other prints: <DUSYI; SYSTEM DUMP INFORMATION NO VALID RELOAD DIRECTORY EXISTS WAIT FOR DUMP TO LOCAL BACKUP RESULT OF DUMP TO LOCAL BACKUP SUCCESSFUL RESULT OF DUMP TO EXTERNAL BACKUP FILE/DIRECTORY DOES NOT EXIST 11:08 16OCT16 FAILED FOR DIRECTORY REL1...
  8. Omissam

    Problem with external bacbkup

    Whosrdaddy ok .... there is a problem I can not remove the hard disck: <IODDP; I/O DEVICE DATA NODE IODEV/SUBFS EQU/BPOS SIPOS VEND/USAGE STATUS SYSN - 001-0-70 - - IN SERVICE SYSN SYDISK1 001-0-70-0 3...
  9. Omissam

    Problem with external bacbkup

    Hello In SP05 This test was already executed but the problem remains: What does the end of the dump: AUM1 00:38 15OCT16 AUM2 00:38 15OCT16 ROM 00:38 15OCT16 DTM 00:38 15OCT16 DATA TIME DATE LIM001 00:39 15OCT16 LIM002 00:40 15OCT16 WAIT FOR CHECK READING OF RELOAD DIRECTORY CHECKSUM ERROR IN...
  10. Omissam

    Problem with external bacbkup

    Help.... I can not make external dump MD 110 BC9 dubdp; BACKUP DATA EXTERNAL BACKUP LATEST PREVIOUS REL1 REL2 NOT VALID NOT VALID LOCAL BACKUP...
  11. Omissam

    Message Operator (OPI)

    Ok! Everything works perfectly !!! I thank you, Inlsp05 and Fcpli for the help you gave me. Bye Omissam
  12. Omissam

    Message Operator (OPI)

    Thanks again inlsp05 [thumbsup2]
  13. Omissam

    Message Operator (OPI)

    Inlsp05 thanks for helping me.[wavey2]
  14. Omissam

    Message Operator (OPI)

    Ok Satellite, however, you are not obliged to give me an answer to my questions. I think that a forum is to help even when the apparatus to be managed is not known at all like in my case for VSU2. However I find it unprofessional to do appraisals or technical assessments of people who do not...
  15. Omissam

    Message Operator (OPI)

    On my MD110 BC12 / sp 10 is located is VSU2 but also a ONE-BOX system, how can I configure it?
  16. Omissam

    Message Operator (OPI)

    How to assign a message of welcome to incoming calls to operators (OPI) Thank you
  17. Omissam

    VSU configured for messages to P.O.

    You should respond to a welcome announcement before sending the call to an operator. Also, when the 'operator is night must take place on closing post offices. How can I do using the VSU board? Thank you
  18. Omissam

    VSU configured for messages to P.O.

    Hello to all how can I configure the VSU in order to record the day / night messages to enable incoming calls to P, O Thank you
  19. Omissam

    NIU2 MASTER HDU7/1 SLAVE

    Hello how to configure a niu2 flash master and a slave hdu7/1 ? thanks
  20. Omissam

    Lim 3 out

    Help me!!!!!! Lim 3 out MD110 BC9 DATE: 28SEPT15 TIME: 19:55:23 CLASS: 4 102 POWER FAILURE DETECTED BY DSU DATE TIME ALP NOIF EQU INF1 INF2 28SEPT15 14:16:45 11 50 003-1-**-** 1 4 94 LIM RECOVERY FROM PLF MODE DATE TIME ALP...