Are you sure that dialed number field is long enough?
Do a CLFOP of the FORM used and look for the fields G and/or G1... (Both of them are maximum 20 characters).
I use this FORM if you want to try...
Check also PARNUM 103:
- 0: Record dialed number in CIL
- 1: Record translated LCR number in CIL
- 2: Record dialed number in CIL. Number is prefixed with Access Code
ALAPI never worked with the AAU. If you know how, just let me know...
Note: The port works correctly cause the agent update the MIB and does the ALLOP without problem.
I have a problem with the LOGONXX.DAT file on the MD. It records the Log-Ins and Log-Outs, but the SNMP Agent of the AAU is entering, for example, each 3 minutes for printing alarms (I have 3 minutes configured on the mdconfig.cnf because I need to see the alarms almost in real time), so the...
Nothing there...
SACOP:UNIT=DER,DSOFF=28&&31,FILNO=6,LIM=9,POINT=3AC;
MEMORY CONTENT ON INDIVIDUAL POSITION
EXE A
FILE NUMBER RELOAD FILE START DS FILE START
6 00035456
POINT RELOFF DSOFF ADDRESS DATA ISO
03AC 0028 00046436 AA...
Well... The MD must know, when a call is received to a diverted extension where to go (it doesn't look on 1650 records), so there must be a place where a relationship between extension and ECF number is written.
That's why I started 'playing' with Signal Trace, doing an ECF to 0666777888 and I...
Talking with a friend about how knowing the external number of an external follow me (with SUSIP only ECF appears), there must be a program with that data.
Just searching with SACOP in UNIT der and rmp, in all filno of the extension LIM with the PTR that SUSIP shows (LINE STATE/PTR), but...
I answer myself:
BLEQI:EQU=1-3-20-0;
FIMOE:SUBFS=SYSSUBFS11;
FIMOE:SUBFS=SYSSUBFS21;
IOSIE:NODE=SYSN,IODEV=SYSDISK1;
Remove the board from the shelf, extract the Compact flash
Reinsert the new Compact Flash
Reinsert de board into the shelf...
Ericsson is going to upgrade the firmware to resolve the problem ;-)
Incredible the knowledge of this forum. Simple incredible ;-)
Another question! :
If I want to use the NIU2+CF System Board also for CIL, how you would do the format of the Compact?
Perhaps 2x64 for system plus 1x120 for...
The moment came, and this happened:
IODDP;
I/O DEVICE DATA
NODE IODEV/SUBFS BPOS/EQU I/O-BUS TYPE/USAGE STATUS AUTH
SYSN - 001-0-70 - - IN SERVICE
SYSN SYSDISK1 001-0-70-0 MASTER SanDisk IN...