Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. MeanGene1987

    How to OUT a CDP and return the DNB's for use.

    the ranges did not exactly all show up. when i added 6601, it added the range of 01-10 i had to add each 10's range in order to get them to start showing up. but the did! thank you for all your help.
  2. MeanGene1987

    missing range of extensions

    OH!!!!!! ok. so when i added 6601, it actually let me. and then the range of 6601-6609 showed up in the ludn. So basically i just had to add a number in each of the 10's block of the 6600 series, and it opened them all up. Thank you everyone!
  3. MeanGene1987

    missing range of extensions

    i did out the dsc of 66, however it still has not released the dn's
  4. MeanGene1987

    How to OUT a CDP and return the DNB's for use.

    When i go to ld 20, and try to prt the dn list. 66 shows as "no act since date
  5. MeanGene1987

    missing range of extensions

    When i outed this, it gave me 66 in the LUDN, but not the rest of the range. i did locate this DSC 66 FLEN 0 DSP LSC RLI 12 Which is pointing the DSC of 66 to RLI 12 which is an old Sip Tie trunk that we no longer use. So now it looks like i need to remove this trunk, but i want to be...
  6. MeanGene1987

    How to OUT a CDP and return the DNB's for use.

    Starting a new thread as previous thread lead me to a new list of questions. I have a CDP, 66 This used to be a tie to another pbx, but is no longer. I need to open the entire range of 6600 - 6699 for use as DN's. (we purchased this whole block as DID's) Could use some assistance in...
  7. MeanGene1987

    missing range of extensions

    ok, so looking at this, i see that 66 is being used as a coordinated dialing plan. I do not have any additional PBX's tied into this switch however there may have been one in the past under previous company ownership. Is it possible to Out a CDP, and if i do so, will that make the range...
  8. MeanGene1987

    missing range of extensions

    DN 66 TYPE CDP STCD DSC
  9. MeanGene1987

    missing range of extensions

    We recently purchased a range of DID's 6600-6699 When i do a LUDN, the 66, and 6600-6699 extensions are not listed. What do i do in order to A. Find why this range is not available, and B. Make this range available?
  10. MeanGene1987

    Nortel 1120 E phone not able to perform lookups

    turns out a late night graceful power cycling of phone system brought all systems back online. was hoping for a command line to restart signalling server however was not able to find one in time and had to restart.
  11. MeanGene1987

    Nortel 1120 E phone not able to perform lookups

    So this is what i get as a result. I'm not certain if i'm reading it correctly but with the state of Link Up, i would think it should be good. How would i go about restarting the signalling sever? do i just need to power cycle the pbx cabinet? NODE ELANIP LDR SRV...
  12. MeanGene1987

    Nortel 1120 E phone not able to perform lookups

    Does the signaling server have a separate IP address from the main server? How do i check to see if the signalling server is running?
  13. MeanGene1987

    Nortel 1120 E phone not able to perform lookups

    Hi all, hope you can help as i'm a bit stumped. We were doing some network reconfiguration about 2 weeks ago, and ever since the networking was done (unfortunately i can't go back) the phones are able to make and receive calls, however they are not able to use any of the advanced phone...
  14. MeanGene1987

    Moving Card to new Slot

    Mikepbxb, Thank you very much. your trick regarding leaving the customer blank was just the ticket. The card has been moved. I'm adding my output below for future admin's having similar problems. REQ mov CUST SRCL 8 DSTL 8 SHCD 0 7 to 0 2 SHCD FORCED DISCONNECT SOURCE FORCED...
  15. MeanGene1987

    Moving Card to new Slot

    So i've been doing a bit more investigation into this which might help shed light on my problem. the cabinets i'm working with are part of a Media Gateway Controller that is separate from my primary PBX which i am logging into. I can login to the secondary media gateway controller as Admin...
  16. MeanGene1987

    Moving Card to new Slot

    This is what i get when i try to mov via ld 25 REQ mov CUST 0 SRCL 8 SCH5235 The cabinet does show 8 on the card. *edit. specified that i tried to mov via ld 25
  17. MeanGene1987

    Moving Card to new Slot

    I am trying to move an Analog Card. I'm having some difficulty with this. I believe it may have to do with the fact that this system is on a different loop. It's listed as loop 8, but when i list the loops in my switch i do not have 8.
  18. MeanGene1987

    Moving Card to new Slot

    I've recently inherited a Nortel CS1000. It's been a few years since i worked on one and i'm a bit rusty. hoping someone can point me in the right direction. I have 2 separate cs1000 stacks. One of them has been out of service for awhile. I have a new building that is being built, and i...