Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. scotford

    CS 1000E Zones

    When I do a STIP ZONE it shows everything reg or unreg to that zone, if I do a STAT ZONE it states no zones configured??the only way I can program a set is to use zone 0, which never existed, and it works??? any ideas.
  2. scotford

    CS 1000E Zones

    Hello, went to add a new 2001 set, assigned zone 2 for set and got a sch009, I checked the status of all zones, it states no zones configurd??? what happend, any ideas I origanally had 4 zones, we had a power outage that brought the switch down not to long ago, is it possible it did not reload...
  3. scotford

    Programming of Nortel Northstar PABX

    Try posting in the Norstar forum, I am sure someone can help you.
  4. scotford

    CallPilot 4.0

    Check the time zone, all is well, will have vendor take a look. Thanks for your input.
  5. scotford

    CallPilot 4.0

    Just got back from vaction and had 6 emails in regards to incorrect time stamp on messages, it is exactly 1hr behind, checked docs was unable to find any info to correct, any suggestions would be great. Thanks
  6. scotford

    CallPilot 4.0

    Tested and works great, Thanks
  7. scotford

    CallPilot 4.0

    Had a request from a user to be able to retain all messages left in mail box and be able to retrieve when needed, can I do this with the archive back-up, is there any other storage solutions??
  8. scotford

    1000E Media Card on 4.5

    Arrived this morning to find my T1 and T2 PRI's were in mbsy state, was able to enable but noticed that I had a media card residing on the T2 that was disabled, tried to enable using ENLC, got a NPR326( no response from card) I have feeling I am going about this in the wrong manner, any...
  9. scotford

    I2002 power supply

    I have noticed this as well, I tested one and have had no issues, probably have a dozen or so in the feild working, have not heard why this has changed?
  10. scotford

    CPND

    Sorry for the confusion, it will accept any name over 17 chrachters up to 27, it won't display on internal calls,(blank screen) not setup for CPND external.
  11. scotford

    CPND

    johnpoole, I have no problem entering the name in without errors, and can even prt in ld 95 and ld 20 and it will appear but will not show on local calling.
  12. scotford

    TM 3.1 error

    Having the exact problem on the same eqiupment and rls, I have heard that possilbly 3.1 has a proplem with FTP, I have the Vendor looking into it, hoping to have a response today.
  13. scotford

    CPND

    GHTROUT, Tried the changes and did not work, it seems I can only get a max of 17 characters, this is my CPND set up. TYPE CPND CUST 0 CNFG ALON MXLN 27 STAL YES DFLN 27 DES NO RESN NO NITC NI
  14. scotford

    CPND

    Thanks GHTROUT, I will check it out monday morning, have fridays off.
  15. scotford

    CPND

    Hello Everyone, Just wondering if anyone konows why, when I enter a name over 16 characters it will not display on the set even now my MXLN is 27, using I2002 sets on 1000E 4.5. Thanks in advance.

Part and Inventory Search

Back
Top