Dear Colleagues,
Could you please, advise us regarding an upgrade from BC12 SP3 to TSW BC13 SP8:
Can boards TLU 25 and TLU 27 be used in TSW BC13 SP8 (&do they need firmware upgrade).
-If they cannot be used, which boards replace them.
We have checked Mittel/Aasra documentation, but for us...
Hi,
We need to replace faulty LSU card on BC 12.
Can we use the following procedure:
1.bldbi:bpos=x.x.x;
2-remove fail card from mag and insert new card there
3-bldbe:bpos=x.x.x,allfm=yes;
No test system BC12 at the moment.
Please Help.
Thank you!
Danail
Dear Colleagues,
at customer site we have an old 3 lim system MD110 BC 6.
All phones in Lim 2 cannot dial out. Also they cannot be dialed from outside. They can only dial phones is the system.
Here is the alarm log
allop;
ALARM LOG
IDENTITY: CULTURE-PALACE
VERSION: ASB50104/10-R2/6/1/C...
Thank you whosrdaddy!
Thank you snor!
Thank you inlsp8!
The trick with pulling the LPU/LSU during FTP transfer was very very helpfull
Thank you,
Danail
Hello Colleagues,
we need some help regarding initial load procedure
We have a test system MD110 BC12, SP7 with NIU2.
During initial load when starting loading lim disposition table we got error message “Already assigned”(on the first row CNLDI) and could not continue with the lim disposition...