Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. gullsinn

    Maipu S3100 switch password

    i am trying to connect Maipu s3100 MyPower switch with putty and unable to login as i dont know the default password and please i want to use it for CCTV cams what configuration it is required Thanks
  2. gullsinn

    Directed Pick-Up cs1000 for 500 type sets

    DPU is Allowed :( do i still need to put Dns in one group ? Hook-Flash Followed by SPRE+3 (default PURN) also did not worked either test this way made a DN ringing dialed from another DN hear busy pressed flash key SPRE+3
  3. gullsinn

    Directed Pick-Up cs1000 for 500 type sets

    Dont know what is tone dialig i setup extensions in same group if i dial *0# or #9 it pick ups any ringing number from all 457 extensions and do not works if i dial #9+DN or DN+#9 i want to force user to dial respective DN in order to pickup when it is ringing it could be very good if DN 111...
  4. gullsinn

    Directed Pick-Up cs1000 for 500 type sets

    Pudn is #9 in cls pu's are A (allowed) buut it does not work it gives fast busy
  5. gullsinn

    Directed Pick-Up cs1000 for 500 type sets

    how do i setup Directed Pick-Up for 500 sets so user see ext 123 is ringng he dials 123 + code to answer or code + DN without puttig them into group or do i need to put all exts into 1 group ? to answer user need to dial Code+DN or DN+Code ? thanks
  6. gullsinn

    an old thread i cant reply in has something i need

    you may try archive.org for gone sites
  7. gullsinn

    Call drops on analog phones

    i connected two nortel cs1K sites through PRI cards distance could be around 2.5KM which i covered with SHDSL ntu 5099b site B can dial within site fine however site B calls are getting dropped within 15 to 20 seconds weather call is ringing or picked digital (m3902)sets do not drop calls. same...
  8. gullsinn

    Coordinated Dialing Plan on same area code 11c

    both sites are connected with PRI and both are DID having same HLOC
  9. gullsinn

    Coordinated Dialing Plan on same area code 11c

    we have two sites i setup cdp which working fine for all other area codes however theses two sites are on same area code on separate e1 if a user calls the call connects/looks for free Chanel on first PRI weather the dialed number is for second site or first in case if 30 chnls of PRI busy then...
  10. gullsinn

    pri card is not sinking

    Sorry i don't understand "btw the lenght of the LDN0 you set is the number of trailing digits it will look at for routing in IDC etc." my LDN0 is 10 on second site (not printed yet on first) and DCH rout is 12 on both sites on first sites DNs are starting from 35500 and on second site DNs are...
  11. gullsinn

    pri card is not sinking

    Ahh here i am stuck on incoming calls i can dial outbound calls from second/both sites however if i call to DN on second site either from first site or or out side the call is not being routed to second site. in INT CTVN is not set to ovf ovf ovf ovf so all wrong incoming calls routed to console...
  12. gullsinn

    pri card is not sinking

    actually it gave a SCH but did not stuck on that and just moved to next prompt which i ignored when i do see it as YES in print
  13. gullsinn

    pri card is not sinking

    Thank you very very much all of you helping to alive a site which our vendor declared as dead and not repairable. not sure if it relates however i configure LDN 0 in ld 15 and CHG ISDN to yes again in RDB soon after it start working you can not set ISDN to yes if LDN0 is not configured though...
  14. gullsinn

    pri card is not sinking

    Here is a print said by bogone21 E1 provider says there is no alarm at there end and seems working fine however i get fast busy when i dial access code ld 73 DDB000 MEM AVAIL: (U/P): 98886601 USED U P: 5318473 64747 TOT: 104269821 SCH5066 REQ prt TYPE pri2 FEAT syti DTA308 12 DTA108...
  15. gullsinn

    pri card is not sinking

    Ahh i found a difference between both sites but dont know how do i change it working PRI site REQ prt TYPE adan ADAN HIST SIZE 25000 USER MTC BUG ADAN TTY 0 CTYP QSDI GRP DNUM 0 DES FLOW NO USER MTC OSN XSM YES TTYLOG 0 BANR YES non working PRI site REQ...
  16. gullsinn

    pri card is not sinking

    both sites are in same room the second site is not a fresh install and it was installed in another city with different city code maybe this could be problem nodeid of first site was 8018 and second was 8015 i added another node as 8018 and make it primary then set old one as false but no luck...
  17. gullsinn

    pri card is not sinking

    we have 2 sites on same location got another e1 for second site i setup pri card for second site with all same values as first one printed in ld 22 cequ adan rdb in ld 21 did in ld 20 stated in 60 and all values are same as first site however second site is not dialing to any out network number...
  18. gullsinn

    tie 2 cs1k sites

    we have 2 sites and want to joint them so users of second site also can have access to send receive calls. we do not have SIP licence have not trunk card have PRI cards on both sites but not authorized to have another E1 from central office can i use single E1 on both sites distance between...
  19. gullsinn

    cs1k problem connecting with procom plus

    thanks really typical i found them in connection directory -> data -> port settings
  20. gullsinn

    cs1k problem connecting with procom plus

    Thanks i wll try to find com port what to enter in IP also i found 7-N-1 VT-100 Standard EC Xon/Xoff Compression: Enabled i only found vt-100 in PC plus did not found any 7 or 8N1 non xon/xof standered ec etc where are these

Part and Inventory Search

Back
Top