  1. Mirko981

    Micro 3700 show RVC in KDS Expo

    Hi Wildbar. I want show RVC Name in the Header (In RED) Thanks Regards
  2. Mirko981

    Micro 3700 show RVC in KDS Expo

    Good afternoon, We need show the RVC in KDS Expo, but in display layout are available only OT or Table, guests, etc. Can the template be modified? Im using 8 Chit Std Dom Display Layout Thanks for your advice. Regards
  3. Mirko981

    Error loading type library/DLL EM Store Micros

    Hi to all, The server runs Micros 3700, 5.5.7 version with EM Store 5.0 , the system is running ok, but today when I tried to run a package(the last one) from my EM Server, I received this error (DAX Error. Error loading type library/DLL). I have uninstalled and reinstalled the EM Client again...
  4. Mirko981

    Backdoor ModPipe attacks POS Systems

    I have read a ESET bulletin about a Backdoor Modpipe attacks POS Systems. ESET researchers earlier revealed that they have discovered ModPipe, a modular backdoor that gives its operators access to information stored in devices running Oracle Micros Restaurant Enterprise Series (RES) 3700 POS...
  5. Mirko981

    Res 3700 error - Unknown unsupervised abort code

    Review the mdshost.xml file en the Workstation, maybe is with an old information. Copy a new mdshostfile.xml updated file from the server. Regards. Mirko
  6. Mirko981

    Labor date incorrect in Time Card

    Hi to all, I have this scenario: - Business date: 2020-07-25 - employee clock in at 8:00 AM at date 2020-07-25 - employee clock out at 14:00 PM at date 2020-07-25 Micros was change business date at 23:00 pm When an employee makes Clock Out, in the table time_card_dtl, add in the column...
  7. Mirko981

    Decrypting Micros SIM files

    Hi WildBar, could you send me the decryption tool please. mirkoalm@yahoo.es Thanks
  8. Mirko981

    Tablet Oracle 721 - Check is opened by Tabletxx - Override check owned by offline UWS?

    Hi to all, We have a restaurant using tablets Micros 721. The table is opened and send the order to the kitchen(and the table is closed in the tablet), but when this table is opened in a Workstation I have the message Check is opened by Tabletxx - Override check owned by offline UWS?. Micros...
  9. Mirko981

    Error in Upgrade from RES 4.7 to RES 5.5 MR1

    Hi Morgelen, I copied the view from another server with 5.5 and after do the upgrade, the message is the same. The last upgrade was yesterday using cmd window and opened as Administrator and the message is different but not complete the upgrade. 02/10/2019 12:27:07 PM Could not execute...
  10. Mirko981

    Error in Upgrade from RES 4.7 to RES 5.5 MR1

    Hi Morgelen, thank you for your answer. I'll do it. I have a question, after copied the view, i must do dm -u, ? Thanks. Mirko
  11. Mirko981

    Error in Upgrade from RES 4.7 to RES 5.5 MR1

    I having a problem when execute dm -u, appears a message in DM.log 11/07/2019 6:04:28 PM Could not execute statement. Cannot use view 'v_R_employee_time_card' because it is invalid SQLCODE=-1040, ODBC 3 State="42000" File: "CreateViews.sql" on line 57705, column 1 11/07/2019 6:04:28 PM **Error...
  12. Mirko981

    Critical error encountered when processing package ID from EM

    Hi guys, i have a problem after run receive from EM Central <EVENTS> <EVENT ID="0" DATETIME="2019-02-21 09:46:14">Log Session (17) started.</EVENT> <EVENT ID="1" DATETIME="2019-02-21 09:46:16">Receiving file "D:\MICROS\RES\EM\TRANSPORT\RECEIVE\S1_D68_C16_P1.MPZ" [1 of 1]</EVENT> <EVENT...
  13. Mirko981

    Database Backup Failed - Res 3700 5.2 MR1

    Thanks Jimmy, I'll try this solution and post
  14. Mirko981

    Database Backup Failed - Res 3700 5.2 MR1

    Hi to all, The server cannot create backup from 5 months ago. In DM.log appears: 21/05/2018 12:23:55 AM DM Return Code = 1 22/05/2018 12:15:57 AM Starting backup 22/05/2018 12:15:57 AM Database backup failed If i use Database Manager, with password keys : 22/05/2018 2:56:42 PM Starting backup...
  15. Mirko981

    EM 5.4 MR1 touchscreen cannot deploy changes

    Hi, i made an upgrade from Micros RES 4.7 to Micros RES 5.4.1 The packet #1 was received sucessfully, but the touchscreens are blank. In the table em_pending_touchscreen are with touchscreen and cannot deploy to the database. In EM log appears this message: UMT 2: Exception trapped in...
  16. Mirko981

    Micros RES EM 5.4.1.236 - Clients Suported

    Hi, I have a Micros RES 5.4.1.236 EM Server, and i have store clients with RES 4.7, 5.2 and i have installed a server with Micros RES 5.4.1.618. In this last server i can't receive packets because Database Version is different. I asked to Micro's representative and they said that i have to use...
  17. Mirko981

    Code 9 - Failed to export report - Micros Res 5.2

    Hi, i have a problem with the reports DAILY REVENUE CENTER DISCOUNTS and DAILY REVENUE DISCOUNTS DETAIL. In micros log appears the message: CrystalEngine | 0 | Could not export report.Could not export report.One or more fields could not be found in the result set. Use Verify Database...
  18. Mirko981

    Cannot install Windows 7 Client on Micros 4.7 or 5.2

    Hi, i have a pc with Windows 7 32, and the CAL Client WIN32CAL119 but it doesn't work. The Server is Micros 4.7 on Windows 2003 R2. In PosConfigurator it is a Workstation type, the name and IP Address of the computer is the correct. Where can i get another CAL Client? When installing, after...
  19. Mirko981

    3700 and WS6. Not loading OPS

    Hi POSN, I have WS6 and it cannot connect to Server 5.2. Do you have the CAL Client for these version? I tried with WIN32CAL119 but it doesn't work. Thanks regards, Mirko
  20. Mirko981

    Micros WS5 COM1 not working

    Hi, when it ocurrs, we always change the rs232 cable and verify dip switch in the printer. Regards