Hi Bickles,
Now I am though with the link using ESS4 as IFC , but getting only number not name.
Avaya doesn't send the AAR digits. You can delete any extra digits in Change route pattern command.
What I found is Nortel is sending additional prefix digits and they have to be absorbed in avaya in...
We have linked Definity switch with Nortel Meredian using ISDN PRI, Q-sig protocol. But I am getting only number but not the name on either side.
Has any one linked Avaya Definity with Medridian and got both name and number????
TFTP is only for software upgrade and for setting default webpage etc., You can set the IP,Gateway , TFTP address, Server Address ,VLAN ID once and it will remain in the memory. User only need to enter extension and password.
You can set these parameters through DHCP also which would enable...
Yes, all the features on page 7 qsig are set to y except centralized attendant.From the same switch I am linking to Siemens also with both the name and number display.
I have linked Nortel Switch(Option 81) with Avaya Definity G3 Si Rel 11 using Q-sig. I get only the number display, not the name. Please any idea what could be the problem. using
IFC- ESS4.What has to be done to get the name display. Avaya is sending the name but it is not displayed in the...
I have linked Definity G3 Si Rel 11 with Nortel switch using Q-sig. I get only the number display, not the name. Please any idea what could be the problem.
In the trunk group already , send name is y.
Is the problem with the internal calls or with the external calls? As the denial event is for QSIG , it appears the problem is with the ISDN link with the service provider for the incoming calls.\!!!
Do you have problem with internal calls?
Thanks Cmawbey , for your reply.
But it seems that your set up is for linking two Nortel switches. I want have set up for linking with Definity,Avaya switch.
Now the situation is imporoved better after I routed the calls through AAR. Details are as follows..
Programmed One DS1 card to link to Nortel.
Settings for DS1 are Bit rate-2.048,lincode-hdb3,sigmode-isdn-pri,interface-peer-master,connect-pbx,protocol-Q-sig,side-a, etc.,
Created sig group with...
I wish to link Definity with Nortel Meridian swithc using ISDN PRI and Q-SIg protocol. Pleas advise what type of interface setting I should use for porper linking. I have problem in calling Nortel switch from Definity. Reverse is OK.
What should be programmed for D-channel IFC? Please advise.
From our experience , we found that TN799c works better than TN799dP which is 100mb. We had outages when we were using TN799DP on VLAN environment. But when replaced with tn799c , it worked fine!!!
Please tell me what is the Interface parameter in Nortel to link with Definity G3 Si Release 11 using ISDN PRI.
I am able to make incoming calls to definity , but not outgoing calls. Please help!!
I want to link Defenity G3Si swithch Release 11 with Nortel Meridian switch. I am able to receive calls from nortel but not able make calls on E1 , ISDN PRI link. I had to supress the two digit access code while receiving the calls. What are the Interface parameter IFC in nortel for linkingto...