I have a Survivable Media Gateway, that I need to Replace with a standard MGC.
The Survivable Site No Longer has any Local Trunking, so the Thought is to Move the Resource back to the Lab, and Reload the Base OS , and keep the resource on the shelf as a Spare ( we have a few other SMG'S)
I...
Thanks KCFLHRC
~
Here's the Update, After much research in the LD 16 Manual, The TIMR Set as programmed provides the fastest Cut-thru to the trunk.
So, the settings posted work very well for access to a Mult-zone page adaptor
I have identified a Loop Start Analog Trunk on a CS1000e that once seized, does not transmit touchtones for about 750 msec. For my simulator, I have programmed a route to match the page route, and use my phone to access the Route with a test set connected to the trunk. The Test set is sitting...
telklass,
Look on the Server that is running the CCMA ~ Crystal Reports is the engine that runs the reports. Often, the Service will Stop or Hang for no apparent reason. By Re-Starting the Service the Historical reports (and all reports) will be available
Regards
Hello Telephonist,
I would not suggest doing this with the stack "Live" . Use proper safety, and do your back-ups, schedule a maintenance window , and power the stack down . I have done this before, and the power plug-ins are very tedious to get in place with the power Off, let alone on . Too...
Kip,
What happens when you try to load the app?
I am not familiar with the 365 environment so I cant speak to that , but I think if you share the steps your taking to try to make it work, that might help to figure out how to resolve .
QSig is the "NEC" Term to connect to dis-similar machines . I would suggest you post in the NEC Forum. I am sure that some of the folks will be happy to assist you
Actually, we are on this Version : Outlook 2013 (15.0.4903.1000)
My Call Pilot and Call Pilot desktop messaging are the same thing, just a different Term
I Think you may be referring to "My Call Pilot " which is a client that can run within the e-mail (Outlook) as a tab. We have it running on some Windows 10 machines, but Not Office 365 ~
Please try to provide additional detail , as I am only taking a "Guess
Look in your system timers at what is a valid call for SMDR to report. Some programmers leave this as default. Always set this to the shortest possible value.
When the Pots line is in an "Idle" state, there is a dc current (that can be measured via a volt meter ) When the line is in use via a direct connect Single line phone, the Voltage state is changed, this is why the Key system "Denies Access" . There may be some parameters that allow you to...
Ok , but in one case we have a site that has (3) 1010 Chassis , (1) chassis has a Survivable CPU ( NTDW59BAE6 ) CP- MG ,and (2) chassis with standard MGC'S (NTDW 98'S W/ NTDW 78 daughterboards ~ Other sites also have Multiple chassis's with (1) chassis holding the Survivable CPU , and the other...
Wow, thanks for the input KCFLHRC ~ We are thinking that we need to take this up with Avaya as a design flaw ~ The "Common" sense approach is if you loose a power supply in a dual Power cabinet, it should be reported ~ regardless if you have a CPU or not
Thank s
Ok ~ So a little more detail ~ The 1010 Chassis are not SMG"S ~ they just have Media gateways in them. We do have several SMG'S in the Network , but the vast majority (18) 1010 Chassis just have Media Gateways at remote closets ~ I am having a difficult time believing that every 1010 Chassis is...
Our Site CS1K Campus, (7.67) has 1010 Chassis at various physical locations. We have our alarms monitored by our Vendor ( Which works very well) . All 1010 Chassis have dual power . Last week, we lost a Power Supply in one of our 1010 Chassis. No Alarm Event Occurred ~ The MGU within the Chassis...
Have a CS1K Rel 7.65 SP5 ~ UCM ver 02.30.0092.00 (6691)
Within Element Manager, when we use the "Phone" tab to modify phones, the Name assigned for Key 01 Does not upload ~
Example Key 00 ~ DN 1234 ~ Name ~ Smith,John
Key 01 ~ DN 2345 ~ Name ~ Smith,John
Both keys are formatted the...