  1. yelhammar

    HPUX LVM using HDLM

    I meant to recover VG. anyway I had a cabling problem that caused the VG import failure and it's fine now. thanks
  2. yelhammar

    HPUX LVM using HDLM

    How to recover a VG using LVM and HDLM? (Hitachi Dynamic link manager)
  3. yelhammar

    storEdge T3 comm port

    I usually used this setup and it works fine: speed: 9600 bauds Parity: None Data bits: 8 Stop bits: 1 Flow control: None
  4. yelhammar

    Merging backup domains

    Hi having 2 backup domains with 2 different masters contolling 2 Tape libraries. Now we need to merge the two masters catalog into only one while still have access to client backup hostory for restores of the master that need to be removed. Thanks
  5. yelhammar

    NBU 5.0 LTO1 and LTO2 media and drives mix

    media type has changed but the backup still failing with unavailable media error.
  6. yelhammar

    NBU 5.0 LTO1 and LTO2 media and drives mix

    I've used vmchange -new_mt hcart2 -m media_id to change the media type.
  7. yelhammar

    NBU 5.0 LTO1 and LTO2 media and drives mix

    how can I change media type to hcart2 for LTO1 medias already configured as hcart ?
  8. yelhammar

    NBU 5.0 LTO1 and LTO2 media and drives mix

    We’ve done recently done an upgrade to STK library by adding 3 LTO2 drives, so actually the L700 is configured with 8 x LTO1 and 3 x LTO2. Withing NBU SSO, I’ve reconfigured storage units with the wizard and it adds a new storage unit of type hcart2. LTO2 type medias add to the robot and placed...
  9. yelhammar

    STK L700e IBM LTO1/2 Mix w/Netbackup 4.5

    1- Removed the old drive from all sharing storage unit stop NBU daemon 2- replaced the drive and map it JNI EZ fiber with new WWN, and issue a reconfiguration reboot (boot -r). Also add the following lines to st.conf for lto2 support: "IBM ULTRIUM-TD2", "IBM Ultrium-2", "CLASS_LTO2"...
  10. yelhammar

    STK L700e IBM LTO1/2 Mix w/Netbackup 4.5

    I've run the following test: For one storage unit, have downed all the LTO1 drive exept the new LTO2 drive to force a backup with this new drive. When a manual backup is strated, NBU loads the tape, then we see the a media write error, the tape is freezed, and it tries for a new tape until all...
  11. yelhammar

    STK L700e IBM LTO1/2 Mix w/Netbackup 4.5

    I've configures the LTO2 drive as hcart type within the storage unit, and also only have hcart medias on the library. But still can't use the new LTO2 drive.
  12. yelhammar

    STK L700e IBM LTO1/2 Mix w/Netbackup 4.5

    You mean even if LTO2 tape drive support hacart tapes, it can not be mixed with LTO1 drives within the same library STK L700 ?
  13. yelhammar

    L700: Changing IBM LTO FC WWN

    While replacing a Fiber Channel IBM LTO1 or LTO2, is there any way to preserve the WWN, so no need to reconfigure the Servers(Solaris 8), JNI driver and to reboot ? Thanks Yelhammar
  14. yelhammar

    STK L700e IBM LTO1/2 Mix w/Netbackup 4.5

    I've recently replaced an IBM LTO1 drive by an LTO 2 FC drive within an 8 drives STK L700e. all cdrives onnected to a brocade 3800 switch, Sun servers with JNI 6460 HBAs also connected to this switch. Solaris/Netbackup has been re-configured to map the new Tape Drive, also updated Solaris st...
  15. yelhammar

    Right way to configure a headless Solaris 8 server?

    If the system does not detect a keyboard while booting, input and output are automatically redirected to the first serial interface (/dev/ttya, often named "A"). You may attach a terminal or another computer (using a crossover serial cable) to this port.
  16. yelhammar

    STK L700e code

    Summary of configuration: SunFire V480 with 3 HBA: Dual Controllers (X6541A) L700 with SCSI control It seems that I've a bad HBA (X6541A: UltraSCSI DIFF Dual Port), I suspected scsi cable, scsi errors "SCSI bus DATA IN phase parity error" fixed after HBA replacement. I've received the L700 code...
  17. yelhammar

    STK L700e code

    Master server is a new SunFire V480 with Seagate LTO Drives, we're experiencing SCSI errors intermittetly, I was advised to use the latest L700 library code I've a CRC login that I've used some months ago but when tried now get access to only entry level libraries L20,L80.. Thanks for your help.
  18. yelhammar

    Path_to_inst

    On a SPARC running Solaris it is ok to remove BOTH /etc/path_to_inst and /etc/path_to_inst.old After removing you should have no problem doing a boot -a OR a boot -ar OR boot -arv The /etc/path_to_inst will be rebuilt without fail unless some other file corruption has occurred. On a x86...
  19. yelhammar

    Changing Master server box and hostname.

    Using NBU 4.5 DC FP3, Have connected library L700 to a new Master server, and trying to set it as new Master/Media while keeping all the old catalog data. It seems that the Control host while priviewing Media lists won't change. How can I change the Control Hostname? Thanx
  20. yelhammar

    STK L700e code

    Where can I find L700e Library code? Actual code level: 2.2.10D Thanx for help