Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations John Tel on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by tyberius_imported

  1. tyberius_imported

    I have a user that acts as the re

    That's good.. i guess where I'm hung up, he is already on a call and will not want to disconnect from it. She joins him as the last call? that would be separate from the call that he is on. Right?
  2. tyberius_imported

    I have a user that acts as the re

    I have a user that acts as the receptionist for the CFO. The CFO will be on a call and then he tells the receptionist to get a couple of more people on the phone for him. She runs to his phone and does it for him. How can I set her up to do it from her phone? Bridged Appearances?
  3. tyberius_imported

    Softphone on Mac

    We have a customer that is using (or trying to use) Softphone 3.2.3.45 on a Mac (Sierra 10.12.3) They say that the Softphone buttons are all grayed out and the app is unusable, until it is moved dragged to a different monitor. Then everything is displayed and works fine. Problem is their people...
  4. tyberius_imported

    1603 IP phone has to have Calll Server entered after reboot

    I don't think there is. Is there anyway to hard code that Call Server address within DHCP or in one of the files used for the firmwware? 46xx?
  5. tyberius_imported

    one-x mobility does not ring in

    Thanks for the heads up Peter! I'm on 8.0.18 and set for 2 seconds, so good there. The guys at Jenne tell me that it should ring in without the Twinning being active. But if I can't make it happen I can live with it, I just wanted a way to pass the CLID and not the DID. I have read that with...
  6. tyberius_imported

    one-x mobility does not ring in

    Okay..I hope that I did this right. Used Monitor default values and then called extension 125 from 143 then let it ring 6-7 times. It did not ring to 1XP mobile client. I turned off twinning and VM on extension 125. Below is the log file. UNICODE-UTF8 enu ********** SysMonitor v10.0 (18)...
  7. tyberius_imported

    one-x mobility does not ring in

    Yes I have twining setup and the number is configured within the app. What i was hoping to do is turn the twinning off with so that 1XP would display the correct CLID and not my DID number. Is that possible?
  8. tyberius_imported

    one-x mobility does not ring in

    I have 1XP mobility configured on an Android and every feature is working fine except, it will not ring my mobile phone when extension is called. When I have my voice mail turned on at the user level, I can see the call with CLID display briefly on the VM icon with an option the Listen/Answer. I...
  9. tyberius_imported

    D100 Base Station will not Register

    Essential license was needed for this to work..Pretty sure I knew that going in but got in a hurry..spent way too much time trying to get this to work on a V1 chassis. Don't want to try that again. Thanks!
  10. tyberius_imported

    D100 Base Station will not Register

    Good call.. I did have it in at the user tab and the supervisor tab. Anyway I think I found the problem. i just realized that I don't have the essential addition license loaded. As soon as I find it I think that will do it. Will update later. Thanks all!
  11. tyberius_imported

    D100 Base Station will not Register

    Good point gknight1 that was enabled so I'm good there. It is not mentioned in the configuration guides as far as I know, so good catch. I was able to duplicate the config on a V2 box and it worked fine, well almost. Everything appears to be configured correctly but I can't login, this should...
  12. tyberius_imported

    D100 Base Station will not Register

    Yes, I have the trunk, extension and user in place. Sent my config up to the guys at Jenne and everything looks good. Also I can view the network settings on the wireless phones and they are correct. So I know the phones can see the base station. But between the base station and the IPO not so...
  13. tyberius_imported

    D100 Base Station will not Register

    IP Office 8.1.67 V1 chassis. I having trouble getting the D100 base station to register with IPO. The wireless phone has a Connection Error displayed. At no point do I see the base station in the SSA program. I moved all of the D100 files to the embedded memory card and configured IPO to get...
  14. tyberius_imported

    1608 finding Router

    Resolved! I found that the http server ip address was incorect. Phones now join the correct vlan.