  1. trentsteenholdt1

    Set up of Fax Line in CallPilot

    Hi Guys, While I like to think of myself as a bit of an expert on the Avaya CS1000 side of things, when it comes to CallPilot I can get confused and lost rather quickly. I'm sure this is quite simple to set up but I'm just not putting the final pieces of glue together to get it to work and...
  2. trentsteenholdt1

    ERS5520 Stack - Change Base

    You change the Hardware Unit numbers around through CLI. Just unplug the switch from the stack, a slave will become the base. Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  3. trentsteenholdt1

    WSS 2360 upgrade

    These notes I have below will work for the 2360 too. Version 7 (something in that range) is the supported releases by Avaya. To upgrade a 2380 switch from WSS Software Version 4.0 or later, type commands such as the following. Note. This example copies the image file into boot partition 1. On...
  4. trentsteenholdt1

    ZESA missing in LD117

    Hrmm, im running release 7. Both on the cs1000 and the branch office. :-/ Cheers for the tip though GHTROUT. Very handy for someone reading this in the future im sure. Cheers Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  5. trentsteenholdt1

    ZESA missing in LD117

    Hi All. Am I missing something with this or is it something like a feature that i dont have? I have a branch office that I'd like to get ZESA working so E911 calls will go out via the branch office PSTN (PRI), but for some reason I'm not getting any prompt out for ZESA either by PRT, CHG, NEW...
  6. trentsteenholdt1

    winscp to transfer files to the Call Server

    SFTP will be fine to get stuff onto the Linux base. Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  7. trentsteenholdt1

    CLID issue - Call routing over SIP to Site A gives bad PRI CLID

    Any ideas out there? Im sure I'm just missing something! Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  8. trentsteenholdt1

    11c SSC upgrade to Rls7.50 database conversion failure

    dont want to scare you, but we had all sorts of dramas with upgrading the DB from r4.0 to r7.0 back in the day. it turned out to be some type of database corruption with zones and the time - of all things. Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  9. trentsteenholdt1

    Phone Timers/Parameters

    Hi Wire12. Looking in two places then. Call tracing in LD80 and your LD86 for RLI, DGT' and numbering plans on a trunk. I'm not 100% following your question though, so i could be leading you on the wrong path. Cheers Trent Steenholdt Systems Engineer The University of Notre Dame...
  10. trentsteenholdt1

    Access via WEB to UCM and Element Manager

    You'll still be able to use Windows 7/ IE 8-9 for UCM just fine - I do it now. Make sure you run IE in compat mode though, as some of the search and menus will not work. If all else fails, XP mode within Windows 7. Trent Steenholdt Systems Engineer The University of Notre Dame Australia...
  11. trentsteenholdt1

    Sip gateways on 2 CS1k rls 6

    No problems jay0324. Just make sure in your NRS too that you have the prefix of say 0 and that the Dialling plan match cdp.udp (CDP - Cordinated Dialling Plan). Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  12. trentsteenholdt1

    CLID issue - Call routing over SIP to Site A gives bad PRI CLID

    Help! lol Please :) I have an issue where one of my sites, Site A is producing a bizarre CLID number that I can't seem to match to any configuration! From what I can see, it doesnt match any of my CLID tables, DGT and RLB or even something crazy in LD90! Here is the scenario. Least cost...
  13. trentsteenholdt1

    Route our site exchange numbers back to a local cdp number (for SIP).

    Awesome - So simple and it was staring right at me! Star for you! :-) Trent Steenholdt Systems Engineer The University of Notre Dame Australia -Great scott!
  14. trentsteenholdt1

    Route our site exchange numbers back to a local cdp number (for SIP).

    Hi All, I have a situation that I would really like some help on. Essentially, I have users within my three sites that are still calling the full number (eg. 00894330xxx) number instead of using 4 digit DN's to reach other sites. Meaning, they're routing out on the PSTN and costing a local or...
  15. trentsteenholdt1

    Sip gateways on 2 CS1k rls 6

    UNASSSIGNED NUMBER means that you have set up the TSC's/ DSC's and RLB's in LD86 and LD87 correctly... But you havent gone into your NRS on either side to create a NRS 'route' so that the number you're pushing to the DCH/Route of your SIP know which Endpoint is correct!. Take a look at your...