I have a 81c running rls 6 that is not completing back-up's and just "hangs" in LD 43 you can not do a DAT or EDD etc, Also in LD 137 'stat cmd reads part of the FMD and 'hangs" both do nothing until they time out about 15 min or so. I know I need to reload with a new compact flash, but can I...
At the server go into C:\Nortel\data and see if the locked file is there, if so delete it. This is where the locked files go! the folder should be empty.
sporty2
What rls are you running? Also do you have Media Cards, Sig servers, CallPilot, Contact Center etc? I have found that when the elan is pulled off the active CPU if the inactive CPU has a network connection, it will fail over. If the e-lan is pulled off the inactive CPU it will not, and if you...
PBXPOWERUSER
This is a PBX issue related to transfering from an application
Rls 6 or below patch p18804_1
Rls 7.x or above you need PKG GL_PLUGIN 409 and then in pdt enable plug in 224 Q01694286 MPLR24676
sporty2
KCFLHRC
That is correct I have a dedicated UCM security server that all elements are registered to. When this one EM element is launched none of the pwds will allow access, although they all work via putty. Any help would be welcome.
Thanks,
sporty2
OK KCFLHC so how can I do it at this point? I am having issues getting to EM on the leader SS. It does not like any passwords, although I can putty CLI to the SS and it is ok with any of the passwords.
Thanks,
sporty2