Hello Forum,
We have to remote dial (modem) into our MMS v2.0 using craftppp login (then use web to access vm). However one of our technicians changed the craftppp password and we can't figure it out.
We can still do voicemail actions directly on the server, however it's in another bldg...
Trunk still OOS-NE and Sig Group still not coming up with loopback jack connected at the CSU. Tested board and all test passed.
I've busied, tested and released (results passed), but still OOS-NE.
Don't know if it's setup correctly, but typed "change sync" and something like the following came up:
STRATUM: 4
Primary: 01A16 Secondary 01B18
CIRCUIT PACKS AVAILABLE FOR SYNC
LOCATION TYPE NAME SYNC
01A15 DS1 DSN Y
Should my new DS1 be a primary or secondary?
thanks!
My DS1 config looks like exactly like yours except "SLIP DETECTION" is set to yes and my DCP/Analog Bearer Capability: 3.1Khz. Yes, I'm using an integrated CSU.
Just changed Trunk Group for Channel Selection to my trunk group. Same result...OOS-NE
So is it possible to bring the Signal group...
Just curious if I'm waisting my time trying to test my end first. Trying to make sure my end is good before contacting provider.
Is it possible to bring up DS1/signal group with a loopback jack to show "in-service".
Thanks!
Thanks. Spoke with provider and we went thru our configs and same thing.
Here's my ds1. Does anybody see anything wrong that my rookie eye doesn't see?
TRUNK GROUP
Page 1
Group Number: 1 Group Type: isdn CDR Reports: y
Group...
This is fustrating :\
I placed a loopback jack on the back of the 120A CSU and ran "test board 01A15" and all test passed. Also get status lights on front of board to match the good T1:
1 = off
2 = Yellow
3 = Off
4 = green
When I do a "status Signal group 3", it states out-of-service. Same...
I did the following and passed, does it mean my end (to the loopback jack) is good?
busyout board 01A15
test ds1-loop 01A15 cpe-loopback-jack = passed
Haven't been able to contact provider yet. Just wanted to test my ds1 end first.
Also on the front of the circuit pack, the four status...
Yes. Using an ICSU 120A & T1 cable. Provider states their link is good.
I'm looking for a way to test from my switch to demarc.
will the DS1-loopback command do anything?
Thanks guys.
I "busy board 01A15, and ran a "test board 01A15" and here are the results (sorry can't copy paste screen from ASA, so re-typing results):
UDS1 138 FAIL
UDS1 139 thru 146 PASS
ISDN-TRK 36 PASS
ISDN-TRK 255 FAIL 8
ISDN-TRK 256 ABORT...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.