Got an update from the Telco, looks like the UMC carrier cabinet they are served by is oversubscribed and thus many customers have been affected by momentary outages etc similar to ours but not as severe. It amazes me how little information flows down to the people that deal with the problems on...
Yes I have tested it using that method. I changed all the cable pairs to the Demarc point and looped back to me and I did get the rls wrong mode message. Overnight there were no losses of frames, no yellow alarms, the PRI is running clean thus far. Only one blip yesterday.. I will see how it...
According to the Telco, they replaced the card in the UMC at the request of the customer. Now the problem has evolved a bit, there are fewer frame losses but now the pri just goes into yellow alarm, drops and then re-establishes. This repeated last night about 5 times. The slip-d and slip-r...
Pcat.. I would tend to agree if the service was net new.. however, the system has been in and working for almost 2 years with no issues other than this one to date.
More monitoring.. watched the PRI loop take a complete dive right at about 2pm, loss of frame caused the PRI loop to reboot, slipd counter jumped up to 17, and then the frame losses went crazy right after that. The counter went up from 9 to 34 in a matter of minutes. I am wondering if rebooting...
You may have to provision another superloop in LD 97 if you are all out of TN's in your superloop. Check licensing under LD 22, prt SLT make sure you are not out of IP licenses. If you have spare cards in your superloop, then just provision a new IP phone on the first unit and then the other 31...
I personally think it came down to economics and that they did not want field tech's removing the PCB's from the system. I have had to do the same thing you did, buy a whole chassis, remove the PS and throw the case away. It is a wastefull way to do things.
The customer forced the telco to replace the card yesterday, so far since they have done that there has only been on frame loss since last night. I will continue to monitor it and keep everyone up to date.
The loopback might prove the card is ok, but you need voice traffic on the pri span to cause frame loss. The pri looks fine as long as there are no B channels in use, once the BCH's start being used up, then the frame losses really start then the card resets the loop.
I have a pri from the telco that is not slipping but about 3 weeks ago the PRI loop started to experience frame losses, no slips etc but frame losses just like this person's thread thread798-1564761 . My system is a CSE 6.0 system with one PRI but exact same symptoms. I have changed out the...
You will loose all your voicemail etc and you will have to rebuild anything thats based on HD storage such as IP sets, networking etc. Backups from one version can't be restored to another but the MSC card data will migrate accordingly.
I have a BCM 50 5.0 machine and I am trying to get it to work with my 6.0 CSE. The CSE 6.0 has nothing BUT 1140 ip sets on it, the BCM 50 5.0 has a mix of sets. When we place a call from the CSE to the BCM 5.0, the phone rings and you can answer the call, voice path works. When you call from the...