Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by mlkerby

  1. mlkerby

    IAX working one way

    There was an issue with the firewall. The peer status is OK now but the Box A still cannot call Box B.
  2. mlkerby

    IAX working one way

    IAX issue I’m trying to connect 2 Trixbox via the internet; both of them are behind Sonicwall firewalls. The following ports are forwarded to each BOX respectively UDP 5060, UDP 4569, UDP 10000-20000. Box B is able to call Box A with no issue. Whenever Box A tries to call the message “All...
  3. mlkerby

    Norstar-Asterisk/Trixbox

    Got it to work. Needed to set Absorblength to 00 in destincation code.
  4. mlkerby

    Norstar & Asterisk/Trixbox

    Got it to work. Needed to set Absorblength to 00 in destincation code.
  5. mlkerby

    Norstar & Asterisk/Trixbox

    The Norstar and Trixbox are connected via PRI. The Norstar has 4 digit extension (2xxx) and the Trixbox (6XXX). When I call the Norstar from the Trixbox, I dial the 4 digit with no issue. When I dial the Trixbox from the Norstar I need the first 2 digit are dropped. The log on the trixbox...
  6. mlkerby

    Norstar-Asterisk/Trixbox

    The Norstar and ZTrixbox are connected via PRI. The Norstar has 4 digit extension (2xxx) and the Trixbox (6XXX). When I call the Norstar from the Trixbox, I dial the 4 digit with no issue. When I dial the Trixbox from the Norstar I need the first 2 digit are dropped. The log on the trixbox...
  7. mlkerby

    Norstar & Asterisk/Trixbox

    I'm looking for some help to insterconnect a Norstar MICS 7.1 with a Asterisk/Tribox via PRI.
  8. mlkerby

    Norstar-Asterisk/Trixbox

    I'm looking for some help to insterconnect a Norstar MICS 7.1 with a Asterisk/Tribox via PRI.
  9. mlkerby

    Caller ID - MICS 7 to MICS 7

    lcs226, I'm using at each end transition Networks T1/E1 TP to Fiber Media Converter (SSDTF1011-100)
  10. mlkerby

    Caller ID - MICS 7 to MICS 7

    Only the business name showed when I did that
  11. mlkerby

    Caller ID - MICS 7 to MICS 7

    This is an example of what I want: If a have a set extension 2253 with name Jane in site A that calls an extension in site B, I want Jane to appear as a caller ID in site B instead of H2253. If I program a business name, the business name will nshow up and not the extension name.
  12. mlkerby

    Caller ID - MICS 7 to MICS 7

    The 2 sites are for the same company and are connected via fiber thru the DTI-PRI and it's configured PRI-SL1. Do I still have to configure the business name?
  13. mlkerby

    Caller ID - MICS 7 to MICS 7

    I have 2 sites with Norstar and MICS 7.1 that are interconnected with PRI-SL1. Site A has DN 2XXX and site B 3XXX. When I call from site A to site B the extension that shows up in site B is H2XXX and from site B to A the revese H3XXX. Is there a way to have it show the name instead of HXXXX.
  14. mlkerby

    Configuring Centralized Auto Attendant (CAA)

    It's in the installation guide but I'm a bit confused on the setup for the Remote System. Any help would be appreciated
  15. mlkerby

    Configuring Centralized Auto Attendant (CAA)

    I have setup CDP between the 2 sites with unique ID digit. I have the steps to setup the centralized voicemail. However, I know that there are additional steps for Centralizing the Auto Attendant and I'm a little confuse on how to configure it.

Part and Inventory Search

Back
Top