Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by jmitchell1980

  1. jmitchell1980

    3com phone issues

    Has anyone ever had any issues on release 6_0_63 with 3102A telephones and paging. What we have found is that if anyone pages from a 3102B phone the page goes through properly. If someone with a 3102A phone pages the NBX locks and reboots. Another odd thing is wecant get into the programming...
  2. jmitchell1980

    NBX paging

    Anyone know what the max # of phones you can have in a page zone?
  3. jmitchell1980

    PCXset with Vista and Windows 7

    Does anyone have pcxset working on a vista machine or Windows 7? Currently on 6_0_63 NBX
  4. jmitchell1980

    Callpilot

    Mike sorry did not see your response, It was hooked up to a CICS with 5.1 SW I believe. I tried every level of SW except 1.1 which I dont think I have. I will try that and you are right it does just keep rebooting. Thanks for all the responses, much appreciated.
  5. jmitchell1980

    Callpilot

    It is a 9V power supply that came off a newer call pilot. I watched it boot up and it waits, and then reboots again, this just continues. When I telnet I get a username and password prompt but have no idea what to enter. Everything on it should still be default IP address is definetely...
  6. jmitchell1980

    Callpilot

    Well it came off a working CICS, I have tried a couple different KSU's and no luck. I was hoping to console in or through the browser and factory default it as I can't get it to come up on a KSU.
  7. jmitchell1980

    Callpilot

    I have a callpilot Mini that was removed from a customer site. The default IP address never changed. The software release says rel 01 2003/02/04. I can ping it and telnet to it (don't know the password to get in though) When I connect it to any norstar system I cannot access it. I am not...
  8. jmitchell1980

    CAS Software

    Thanks for the reply. I mis typed the software version. It is 6_0_63. I believe we installed 6.0.6, it looks like we installed the incorrect version of the CAS software. Where did you find that information, do you remember by chance?
  9. jmitchell1980

    CAS Software

    We recently upgraded a customer from 4_2_15 to 6_0_69 and installed the latest CAS software at reception. It worked fine for a few weeks but has now started to get laggy and unresponsive at times. I am wondering if anyone has the system requirements for this software, nothing has been updated...
  10. jmitchell1980

    Caller ID

    Thanks for the replies I got it figured out, needs to be set to national
  11. jmitchell1980

    Caller ID

    I have never written a pretranslator to include that. What would it look like, I do have a pretranslator to send out the CLID and it does show in the test tool, however it does say that it would send the number but the type is unknown. I just checked some other customers dial plans and that...
  12. jmitchell1980

    Caller ID

    Just upgraded a customer from 4_4_12 to 6_0_63, multi site but I only have an issue with only 1 of the sites with a PRI, since the upgrade every call that goes out shows up as unknown. I have checked the pretranslator and used the test tool and it does say that it is sending the correct CLID...
  13. jmitchell1980

    PCMCIA Card for option 11

    Does anyone know where to get these cards, I have seen some online however most have been discontinued. Any help would be great. Thanks
  14. jmitchell1980

    IP Phone(s) Out of Service

    Enough licenses? Make sure on the switches you have capacity and that the system is in license compliance.
  15. jmitchell1980

    VCX: is there a "flash hook" feature

    You would need it for analog lines with call waiting. It doesn't exist on the VCX. I doubt this will help but feature + 260 is a hook flash on a NBX. You could give it a try.

Part and Inventory Search

Back
Top