Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations John Tel on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by ebcmm01

  1. ebcmm01

    BCM 2.0 Company Greetings

    This trouble has now been resolved. The problem with the Greetings not working was caused (by the dufus (me)) from assigning the overflow point for the HG to the VM DN. Thank you Dasheen and Snowman50 for your assist. Happy New Year.
  2. ebcmm01

    BCM 2.0 Company Greetings

    Yes the AA is set to answer after 4 rings. L61 and 62 are assigned to be answered by the AA. This was working fine and everything is working with the exception of the Company Greeting being skipped.
  3. ebcmm01

    BCM 2.0 Company Greetings

    I installed a BCM50 which worked great for 2 weeks. The calls are supposed to ring in on a hunt grp key(2 sets Loc221 and Loc222),ring 4 times and if unaswered are then answered by the AA. After a few seconds the call then rings back at Loc221 on the intercom key(rings 5 x's)and if not answered...
  4. ebcmm01

    Message indication on a CP100

    That is what was causing the problem DigitelD. Thanks...you get a Star.
  5. ebcmm01

    Message indication on a CP100

    Here is an update. The GMB is disabled. The MB is 221 and is assigned to 221. I tried a different set(that I know is working properly) and no change. The M7208's are Rel 16 or newer. I tried an M7310 (REL 23)and the MSG shows up correctly. Changed the port and MB to 224 to get her going. I will...
  6. ebcmm01

    Message indication on a CP100

    Good suggestion norstarboy. I am pretty sure that the VM Box is assigned to 221 but I will look at the status of the GD because it may be a conflict if it has somehow become enabled. Thank you.
  7. ebcmm01

    Message indication on a CP100

    Yes the extension is assigned. Everything was working fine until a power outage and the only thing that appears not to be functioning correctly is Local 221 MBox. Is there a way to reset the Message indicator so that I don't have to do a STARTUP on this CPilot?
  8. ebcmm01

    Message indication on a CP100

    I am trying to resolve a problem on a Call Pilot 100 SW 3.1 and a CICS with SW 7.1. The Receptionists set (221) does not indicate a 'Message for you' when there are messages. The message indicator box is enabled. The other users do not have this trouble. I restarted the Call Pilot and this did...
  9. ebcmm01

    Call Pilot on a CICS w 4.1

    The CP is set to answr lines after 7 rings. What you are supposed to hear is the Company greeting and then the CCR menu. What you get though is 'The person that you are trying to call is unavailable' and the it goes to the CCR Menu 0. All set programming has been checked to see if any are call...
  10. ebcmm01

    D816 Volume Problems

    This issue has now been resolved. The customer is putting in another system. I will note that you have a 1232 cwc3. Thanks again.
  11. ebcmm01

    D816 Volume Problems

    Upon further investigation, the first 4 lines are on the motherboard and it is decision time....buy a new KSU (Norstar which I like better) or a used D816 Hybrid. The choice now depends on what the customer wants to spend.
  12. ebcmm01

    D816 Volume Problems

    Thank you cwc3. No Problem with line voltages and no problem hearing at the demarc. I will change the CO Line card.
  13. ebcmm01

    D816 Volume Problems

    There was a bad CO Line position on this unit about 1 year ago so I moved the Line to CO position 3. This worked great....until now. The customer is experiencing problems with being heard on an outside call. The customer can hear fine.....just the outside caller has a volume problem. This is on...
  14. ebcmm01

    D816 Hybrid

    Thank you cwc3. This solves this problem. I am a little concerned that since CO1 is now bad, how stable are the rest of the trunks. Are there shared circuits that will now cause a failure in CO3?
  15. ebcmm01

    D816 Hybrid

    When you go offhook, how do I make a CO line the prime instead of the intercom?

Part and Inventory Search

Back
Top