If this is a 200ICP check your CPN settings in forms 19, 22 and 54. I had an issue not long ago when a fiber was cut and the carrier rerouted service to another location. When that happened outgoing calls stopped working. The CO calls were routed to wasn't seeing the correct number of digits...
I have an MXe-III platform running SP 8.0. This replaced an old Avaya G3 that used bridged appearances, and I set up Group Park for them to use so they could answer incoming calls but pick them up from another phone if/when necessary. The Group Park feature works great except that the phone that...
I have a site that received new 5330 IP sets but was unable to register them, showing L2 DL Error. Upon investigating I found this was due to the software level in the PBX, so the PBX was upgraded to 5.0.2.14. Once the upgrade was complete and PBX restarted the 5330 sets registered successfully...
joe2938 - my apologies as I see I wasn't clear. I do have a TN464 installed but according to documentation I also need the TN778 packet interface to support the D-channel signaling if I'm understanding it correctly. I did try setting up the trunk group but when I attempted to program the...
Can anyone confirm if a G3siV6i.02.1.125.1 will support a PRI? I found documentation indicating it IS possible when using a TN778 but the PBX itself will not let me install it, I've verified that the licensing has ISDN-PRI set to yes. I've never installed a PRI on anything this old before, if...
Thanks, you were on the right track. Looked further into this and found that LDN0 was removed as it was previously thought unnecessary...(d'oh!).
Programmed a generic 4-digit ext for LDN0, problem solved.
Nortel CS1000 rel 3.0 - For an unknown reason all incoming DIDs are suddenly ringing the attendant console instead of their respective phones. The incoming digits match the extensions so there is no IDC table, and no changes have been made to any route. DIDs are coming in on a PRI so I was able...
SherWat - thank you! I did verify that we have package 127 and DSX listed in the FTR_DATA. How do you specifically test the functionality of the CTIA? I have no experience with these.
Trying to add an M3905 phone to a CS1000 rel 7.6 with a CTIA module. Documentation on the CTIA says you need CLS DSX (or DSI, can't tell for sure), however I'm getting SCH0341 when trying to make the CLS change. My guess is a missing software package, can anyone confirm? I have found very little...
I have two option 61Cs tied together with a PRI. I have been seeing issues with the circuit bouncing and there appears to be slips occurring as well. Hardware has been replaced on both ends and the two buildings are linked via fiber so there doesn't appear to be a cabling issue. I am suspecting...
I am using 9611 phones and when the user is on an active call the other end will suddenly hear music as if the user put them on hold. The music will play for a few seconds, then reconnect without the user ever placing the caller on hold. This is happening to several phones but I've never heard...
I did attempt to set the trunk type as DIOD, but my signaling options are immediate or wink and these are standard ground-start trunks so I don't think it's going to work.
When attempting to build a new CO trunk group using a TN429D, I'm getting a message saying object and port types are inconsistent when I try to program the port assignments. Any suggestions?