Hello all,
Is there a limit to the amount of remote shelves that a CS1K can have hanging off of it? I currently have two remotes and 5 shelves in the PBX itself.
Thanks,
Nick
Hello,
i read this thread and just wanted to clear up: http://www.tek-tips.com/viewthread.cfm?qid=1494799
so every TN must individualy be cls: cfxd and cfw 4?
thanks
ok, i have changed the code in ld 57:
REQ prt
TYPE ffc
CUST 0
CODE mtrc
CUST 00
FFCT NO
MTRC *57
I also ensured that the TN was programmed with cls: MCTA, but still not showing up on the MAP when i test call it.
All set. I actually went into ld 15
REQ: CHG
TYPE: NET
CUST: 0
<ENTER>
<ENTER>
<ENTER>
<ENTER>
FTOP: FTLY (from FRES)
That took care of it.