Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Extinguish

    T1 clocking.

    TRCK PCK <--- THIS WILL PLACE CLOCKING ON PREF IN LD 60 IF THERE IS A LOOP UP & SET TO PREF UNDER LD 73
  2. Extinguish

    Mysterious PRI message

    I have seen these errors on my switch before & still from time to time. Someone once told me that they're protocol errors & usually coming from the carrier side. PRI errors are additonal "features" that Nortel doesn't support, features that are coming from your CO that AT&T type switches use...
  3. Extinguish

    XMI000 28 : Msg from shelf 0: XPEC error #0001

    Janaya - yes, "AUD000" - "AUD017" - "AUD019" - "DTC001" - and occasionally TFS402 & TFS501 errors. My switch is running: VERSION 3011 RELEASE 24 ISSUE 25 + MDCS03 NA00 -Thanks
  4. Extinguish

    XMI000 28 : Msg from shelf 0: XPEC error #0001

    This would be related to voice traffic... Thx
  5. Extinguish

    XMI000 28 : Msg from shelf 0: XPEC error #0001

    It appears that this "XMI000 Error" is occuring on several super loops. Such as "XMI000 68, XMI000 84, XMI000 28,XMI000 36. We do utilize IPE. I don't believe it to be the controller if it's happening throughout the switch. For each "XMI ERROR", they are all the same format i.e. "XMI000 ## : Msg...
  6. Extinguish

    XMI000 28 : Msg from shelf 0: XPEC error #0001

    Thank you for your assistance - I'll mostly be replacing the controller card. Thanks again.
  7. Extinguish

    XMI000 28 : Msg from shelf 0: XPEC error #0001

    I frequently receive error: "XMI000 28 : Msg from shelf 0: XPEC error #0001" on my Meridian-81c. Can anyone provide any assistance as to a possible solution? Thanks.

Part and Inventory Search

Back
Top