Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. philcap

    CLID on IFC D100

    Bye the way here is the net_data config...I forgot to include. REQ PRT TYPE: net TYPE NET_DATA CUST 0 TYPE NET_DATA CUST 00 OPT RTD AC2 FNP YES ISDN YES PNI 3705 PINX_DN MBG 0 BSGC 65535 PFX1 PFX2 HLOC LSC RCNT 5 PSTN NO TNDM 15 PCMC 15 SATD 1...
  2. philcap

    CLID on IFC D100

    Hi How could I put a default CLID in a PRI, D100 IFC. When an analog line (500 type) make a call over this PRI route their 4 digit line number was send instead a default CLID. Below is my config. **************************** ADAN DCH 15 CTYP MSDL CARD 01 PORT 1 DES plexus USR...
  3. philcap

    Call Reference Value

    Hi john, I enable the serv in LD 96 but it doesn't help, so I disabled it again. Is there any way I could change the call reference value? and the length of the Channel ID? Isn't it those parameters are hard coded or built in the system? Thanks,
  4. philcap

    Call Reference Value

    Hi, Is there away I could change the "call reference value" in the Meridian Option 11c rel 24. I'm using an ISDN with IFC D100. I made a test call, and test call was failed. The call was release by Meridian with a cause value of 100 (means invalid parameters content).The Telco suggest that...
  5. philcap

    Problem in Meridian PRI - D100 Interface

    Hi jgideon, I copied exactly the DMS paramaters you gave me an I still have the problem. Can you please take a look on my Meridian setup in the first part of the email if this is correct. In the DMS side the b-channels are idle but once I BSY,RTS it will be back to IDL, and in few seconds (15...
  6. philcap

    Problem in Meridian PRI - D100 Interface

    Hi jgideon, Thanks for providing me more informations...it really helps. What table does the "SPMECIDX 1" was defined? What are the parameters involved on this. In table TRKSGRP we use DEFAULT for the PARMNAME (instead of NMDSP) and set the location to PVTNET (instead of USER) GLDUSHIO1150 0...
  7. philcap

    Problem in Meridian PRI - D100 Interface

    Hi jgideon, Here's the translation information in the DMS. Thanks for your help TABLE: TRKGRP >fp;pos testcname1062 TESTCNAME1062 PRA250 0 NPDGP NCIT UCS MIDL NIL 0 NIL (ISDN 199) $ 0 5 3_1KHZ 16 $ >table trksgrp TABLE: TRKSGRP >fp;pos testcname1062 0 TESTCNAME1062 0 DS1SIG ISDN 15 15 87Q931...
  8. philcap

    Problem in Meridian PRI - D100 Interface

    Hi Cpm23 Yes, I tried COT, DID and TIE, but nothing works. Any other ideas you had in mind to fix this problem please. Hi jgideon, In the DMS 500 I set the field PROFNAME to SL1PROFL with the ntnapri in Table LTDEF. I also tried the IFC S100 but I got the same problem when using the IFC...
  9. philcap

    Problem in Meridian PRI - D100 Interface

    Hi johnpoole, I enable serv already and chaged the RLS in LD 17. I still have the same problem. I also play around with the RLS from 26 to 37 and dis/enl the MSDL and DCH everytime I make a change. I don't have much luck in making B-channel works. Do you have any PRI connecting to DMS 500...
  10. philcap

    Problem in Meridian PRI - D100 Interface

    Hi johnpoole When I did the stat serv in LD 96 the stat of the D_Channel was DSBL. Do I need to enable it? What is the command to enable the serv. >ld 96 DCH000 .stat serv DCH 015 SERV : DSBL I really appreciate your help THANKS!!!!
  11. philcap

    Problem in Meridian PRI - D100 Interface

    Have you dealt with a carrier using NTNAPRI in a DMS 500 before. I tried D250 and then moved to D100. Both come back on the proto analyser and say that the Meridian is terminating the call since it does not understand/or like the message back from the DMS. The Dchnl is running fine but the...
  12. philcap

    Calling Name Display

    Hi I have a PRI trunks. Would it be possible to send a Caller Name on the PRI for my outgoing calls. How it would be setup in the Option 11C? Can anybody please give me sample datafill? On the other way around how's my phone 500 type (it has a display) would be able to received an incoming...
  13. philcap

    Fast busy after one RING

    Hi Where can I adjust for my incoming call to 3075. I defined the 3075 to LD 14 atdn to automatically ring the phone. My problem is after one, it cuts-off and caller to the 3075 got a fast busy tone. Is there any way I could correc or adjust in the Option 11c. Below is the translations I...
  14. philcap

    CLID on PRI

    Hi I have a PRI trunk. I want that all calls going out/or routed this PRI will used the same CLID. Is this possible How could I don it in the Option 11C. I'm using 24.X release. thanks
  15. philcap

    Configuring PRI trunks in Meridian Option 11c

    Hi johnpoole >ld 21 PT1000 REQ: prt TYPE: ldn TYPE LDN_DATA CUST 0 TYPE LDN_DATA CUST 00 OPT XLDN DLDN NO LDN0 3500 LDN1 3510 LDN2 LDN3 LDN4 LDN5 ICI 00 LD1 ICI 01 ICI 02 LD0 ICI 03 ICI 04 ICI 05 ICI 06 INT ICI 07 MWC ICI 08 RLL ICI 09 DL0
  16. philcap

    Configuring PRI trunks in Meridian Option 11c

    Hi Johnpoole, The PRI-ISDN B-channel was associated to Rout 99 which TKTP is ISA and then the SVRT I associated my outgoing to Rout 97 -TKTYP is COT and my incoming to Rout 98-TKTYP is DID. Did I made my PRI config correctly? Please see my config in the first part of this email. THANK you very...
  17. philcap

    Configuring PRI trunks in Meridian Option 11c

    Hi johnpoole, Where can I check the the ldn setup? In what overlay should I go tho check if it accept 3 or 4 digits. I think the B-channels are not in sync. Once I blocked the B_channels it will not comeup to idle anymore. Also, can you give me a sample how I translate an straight T1 (24...
  18. philcap

    Configuring PRI trunks in Meridian Option 11c

    Hi Johnpoole, I really appreciate your time and response on my problem. I changed the TRMB to no, still doesn't work. I try to change the DSEL (right now it was setup as VOD) to VCE asas you recommended in LD 16 but when I try to do it, the DSEL field did not come up. What overlay shall I...
  19. philcap

    Configuring PRI trunks in Meridian Option 11c

    Hi I'm new in the Meridian and I have a hard time figuring out what's the problem in the PRI that I setup. Can anybody help me please, The D-channel come up but the 23 B channel did not come up. The T1 is between Meridian option 11c and DMS 500 Below the config I made in the Meridian I really...

Part and Inventory Search

Back
Top