  1. cuneyt2020

    NIU board is failed and dump problem and error 109

    Hi, The problem was like this: REL2 was empty, no file was on REL2 and after ficri fimoi... etc, it's ok. But now the NIU card still fails. RFBOI:bpos= 1-0-70 fails Also after executing dump, on standby side it gives an error and after dubdp; i see that on standby side...
  2. cuneyt2020

    NIU board is failed and dump problem and error 109

    to whosrdady: Ok i'll restart it but it's a busy switch and i think it can effect to traffic or lims.. i think i should do this in low traffic case to slash50 we have 24 CSTA links and MIS connections so we use all of NIU cards for outconnections
  3. cuneyt2020

    NIU board is failed and dump problem and error 109

    Hi System is BC10 CN144 and trying to dump, it says command lost... These logs were two days ago. DATE: 20DEC05 TIME: 21:39:05 CLASS: 2 109 UPDATING OF DATA ABOUT THE I/O SYSTEM HAS FAILED DATE TIME ALP NOIF EQU INF1 INF2 INF3 20DEC05 19:45:08 12 1...
  4. cuneyt2020

    CCM server with dual CPU machine

    Ok then i think we should try it. Thanks for your help
  5. cuneyt2020

    Problem with queue in CCM 4.0.5

    Hi thread806-1156557 is the problem we faced mostly, but it consists the problem of yours. And in fact i think it's not the CCM server problem , it's MIS problem in MD110 so the problem is on DCTPP (Also DCTAP restart may fix the problem but it effects to CTI system, so first of all trying to...
  6. cuneyt2020

    Problem with queue in CCM 4.0.5

    Hi, we have CCM4 SP3 and this problem occurs vey frequently. and actaully i fix this by below.. 1) stop ccm services 2) restart the DCTPP units on the lims seen on ACFUP command 3)Start the CCM services. I had a topic before about CCM and this is the same case that i faced, I think the...
  7. cuneyt2020

    CCM server with dual CPU machine

    Hi, On ericsson documents it tells that CCM4.0 is not tested with dual cpu servers Has anybody used it on a production system? We have a free server with dual CPU and we want to install it to this server.. Thanks for the replies.
  8. cuneyt2020

    Question about DISA

    Is it possible to use service codes such as *21* or *24* with DISA in any version of MD110 What i want to do is, sometimes, i ought to divert some huntgroups or ACD groups to others when i 'm at home and if it's possible with DISA, it will be easy to do it. Rgrds.
  9. cuneyt2020

    CCM 4 or DCTPP problem

    Hi, System is BC10 CN143 Sometimes (2 times per week) While checking links on Md110 with ACFUP command i see that links are down... But in this case CCM services are up on the server and after restarting services of CCM4, ACFUP seems up, but in fact it doesn't work. CCM is not refreshing. So...
  10. cuneyt2020

    DNA RDS synchronization only for ODN-ADN-ACD match

    Hi thread806-794664 is archived. So i need some answers regarding this thread . How can i find a md-support command description document? And my other question is, will the command below synchronize the ACD-ADN-ODN info or only ODN-ADN match is done? C:\DNA_S\SHARE\BIN>mds /site:1...
  11. cuneyt2020

    Fax server

    We have Ericsson Bc12 system with Rightfax server using Brooktrout E1 card And here are the parameters that is configured on BC12 <RODAP:ROU=74; ROUTE DATA ROU TYPE VARC VARI VARO FILTER 74 SL60 H'00000350 H'15580000 H'44200010 NO END <ROCAP:ROU=74; ROUTE...
  12. cuneyt2020

    Fax server

    The critical point is, when you configure a route t faxserver, if 8 of trunk is licensed in Fax server, then you should remove the rest of trunks in md110, only 8 trunk should be added in MD110 route
  13. cuneyt2020

    CCM4 SP5 problem

    Hi, due to problems on clients in CCM4SP3 we tried to upgrade CCM server(Win2k server) to SP5.. As Ifor has problems on win2k, we are using NT server for I4LMD service So the clients are configured to use other Ifor server (WinNT server) But yesterday after we tried to upgrade the system to SP5...
  14. cuneyt2020

    CCM client error (Can not connect to database server)

    Actually i don't know if there is any conflicting software done but, on win2000 , i checked the odbc connection part on Administrative tools menu... And saw that there is no related user or system dsn on odbc connections.In fact i'm not sure if there will be one. So i added a connection to...
  15. cuneyt2020

    CCM client error (Can not connect to database server)

    Hi, 3 of CCM clients getting same error two days ago. Actually i uninstalled th CCM client and reinstalled it but still gives the same error (Cannot connect to Database server, No ccm server is available) and after this message it's closed. What can be the reason for this? Note:Other 40...
  16. cuneyt2020

    Operator console doesn't ring

    Hi, One of our customer upgraded their switch to BC12SP1. After upgrading they have a problem with their operator console. Sometimes the console doesn't ring, just shows calling number on display so they understand there is a new call. It's not a good situation for them. The product No. of the...
  17. cuneyt2020

    External Foll.me doesn't wok for some numbers for same extension

    Hi daddy, First of all your advice is ok and now external follow me is ok for dest 0053 by changing d2 and d19 But my first problem is different then you mentioned. Let me explain... Telecom A...
  18. cuneyt2020

    External Foll.me doesn't wok for some numbers for same extension

    Another note is, when i changed the ADC parameters of dest 0053 same as the 00216's ADC parameters, seen on above, alternative choice didn't work.
  19. cuneyt2020

    External Foll.me doesn't wok for some numbers for same extension

    <rODDP:dest=0053&00216; Hi daddy this is the old config if it's possible i want to change ADC of 0053 with the correct one( only changing the related parameter. The critical point is i have alternative route for dest 0053 and the alternative route is in...
  20. cuneyt2020

    External Foll.me doesn't wok for some numbers for same extension

    Well you're right daddy, when i change the ADC parameter to the right one it's ok for external follow me, but i will try to find which adc parameter is related with it. And it's really hardwork to do because it's a production system and i can not try it by removing the destination and creating...