This docuement helped me ALOT! I'm not the author & I didn't use IIS but rather hfs for the HTTP files but it worked for me! https://files.engineering.com/getfile.aspx?folder=627f938c-8cdf-4822-9d0a-1aa6740f09db&file=Avaya_Vantage_K1x5_setup.pdf
I have a K175 phone working just fine on my IP500v2 System however once I make a call to anywhere (even to Voicemail) the phone stops responding to DTMF? I have called outside auto-attendants & cannot dial any options & again...even when I call my own voicemail(*17), it connects just fine but no...
Yes, tlpeter...I've tried that but nothing happens. I've also tried to do the 3.2.999 upgrade & it seems to work but still nothing? The module LED stays RED & is not recognized by the control unit. I've created a new config with the necessary licenses & IP settings, included the DS30 module &...
Just upgraded a 406v2 @ 5.0 to a new 500v2 @ 8.1, everything except a DS30 (500v2) upgraded fine. I have tried everything including DTE w/AT-X to no avail, DS30 just stays Red! Term prog says "tftp load poll fail"? I've even tried using 3rd party tftp program! Any ideas or is it "bricked"?
I just upgraded an IP500v1 from 7.0 to 8.1.57, everything went fine but after the upgrade...we are not able to make outbound or receive inbound calls. Internal calls work fine, the Voicemail is working but no trunk calls. The PRI shows all trunks are "in-service" & idle. There are NO alarms on...
Yes, as I mentioned...watching the TFTP log, I see the new file "holdmusic2.wav" upload to the control unit so it seems to be getting to the IPO...just not playing? I have even tried renaming the file to "holdmusic.com" & it works so there is not a problem with the file I am using...just the name?
I am trying to use multiple sources for MOH on an IP500 running 5.0.18. I can use the external source as the system source & if I use "holdmusic.wav" as the secondary source (for a specific hunt group as an example) it works fine but if I try to use "holdmusic2.wav" as a 3rd source...magic no...
Hey all...we got it working!!! It turns out that the "Replacement" processor that Avaya put into the switch was bad! Everything except the PRI was working but we supect that the Packet Bus in the processor was bad. We replaced the processor today & voila! It's amazing that everything...
We have tried EVERYTHING including AVAYA TSO to no avail. Qwest PRI out of a DMS100, Qwest verified circuit is working to thier Agilent Advisor. We cannot get D channel up? Any suggestions here?
G3csi R7
Ok...same here. What is the next step after you enter "B"? The system restarts & just returns to the "Enter Boot Command" prompt. How do you get to the login prompt