Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Radoje

    LZY 2030801/3/R1A - is it BC8.0 or BC8.1 ?

    Hi Whosrdaddy, Thanks a lot ! Best regards, Radoje
  2. Radoje

    LZY 2030801/3/R1A - is it BC8.0 or BC8.1 ?

    Hi, CADAP says that software version is LZY 2030801/3/R1A Is it BC8.0 or BC8.1 ? Best regards, Radoje
  3. Radoje

    WLAN IP-Phone

    Hi Lalrl, in April 2006 /// announced that they will introduce wireless LAN IP phones. 1.step - Spectra Link access points and phones will be implemented 2.step - /// will develop it's own system
  4. Radoje

    Remote installation of DECT base stations?

    Maxl, it cannot be done. you can only put a new LIM on a remote location.
  5. Radoje

    BP250 PASSWORD

    wfk, Only the "cold start" of exchange will bring you back default password 33333. Unfortunatelly all the exchange data is erased in that case.
  6. Radoje

    MD110 and V5.2 signalling???

    No way, V5.1 and V5.2 are not supported. The only interface that is supported is CAS, take a look at "CAS extension EL7" in Alex documentation. I played with EL7 in combination with UMUX1500 multiplexer(Ascom - Keymile) and it works OK.
  7. Radoje

    Faulty TMU board in BC.10

    you should first do some function tests: FTTDI:LIM=2; for tone receivers and senders FTMDI:LIM=2; for multiparty circuits
  8. Radoje

    CAS tie lines

    md110user -Put MFU board in same LIM where TLU76/3 is. -Don't forget to include A5 signal in signalling protocol.(D6 in VARO). A5 signal is caller ID request, if you are using CCITT R2 MFC signalling. -Do not use simplified MFC signalling (D7 in VARI). regards Radoje
  9. Radoje

    Firmware downgrade for Elu29

    Hi Pete I worked in an OMNI factory for about 5 years. Then instead of CEM&PEM, I started working with LIM&GSM :) Regards Radoje
  10. Radoje

    Firmware downgrade for Elu29

    OmniS3Tech..... Are you experienced with OMNI S3 from GTE/ATEA? I spent many hours working with it.... regards Radoje
  11. Radoje

    Have some fun - MD110 commands

    ...and my colleague says that ASPAC is well-known abbreviation for Asia-Pacific.
  12. Radoje

    Have some fun - MD110 commands

    Altavista found following links: NADAP - Navy Alcohol and Drug Abuse Prevention Program Asian Language Legal Intake Program (ALLIP) Californians Against Discrimination and Preferences (CADAP). www.cadap.org Colorado Advisory Committee on Arson Prevention (CACAP) :)
  13. Radoje

    Dial-in and Dial-out

    In my opinion, the only way to stop data traffic is to know which telephone numbers belong to internet providers and make restriction on dialing of this numbers. Maybe, if you are using ISDN towards Telecom, you could play with bearer parameter of the route (BCAP), or with bearer conversion...
  14. Radoje

    MD Hotel (HA)

    You can contact torres@diavox.com if you want to buy HSM (Hospitality Server Module)directly from Diavox.
  15. Radoje

    GJUL4 link wothout GS

    Hi Extension Manager ! You should put GJUL4 boards in same position in both LIMs. Once I did not take care about this rule and I could not do the backup on HDU. Backup always stopped at one of the program units. Try it yourself...
  16. Radoje

    Ericsson BP250 ?

    Hi Arnoldnt, Main difference between MD and BP is capacity. BP can have maximum 200 extensions, in a hotel version you can put 288 extensions, because room-to-room traffic is very low. Trunks: officially 60 trunks are maximum, but I have a 90+ trunk system working OK, the only limitation is max...
  17. Radoje

    Industry recognised MD110 certification

    My experience with certification: In 2001/2002 Ericsson had cooperation with VUE (www.vue.com) and a lot of exams were offered, including MD110, BP250, applications,...etc. I have passed the following: 10-026 MD110 BC11-Basic 1 10-027 MD110 BC11-Basic 2 10-028 MD110 BC11-Install Large &...
  18. Radoje

    MD110 BC6 - 12 years old...

    1)You can allways upgrade BC6 to latest version - it is BC11 today. Approximatelly 10% of boards will be changed, and new software added - it will cost you less than a new exchange. The only problem is that DC/DC converters in BC6 exchange are "phased out" - Ericsson does not make them...
  19. Radoje

    Interconnect two MD110 by 4 wire cable

    ASCOM COLT-2 is good solution. You can also try new version named ASCOM Music 200.
  20. Radoje

    IVM as overflow position for ACD group?

    Hmmmmm....I don't know....I should check it...

Part and Inventory Search

Back