We haven't solved it yet. At the very most we were seeing it once or twice a week. Our view was that it probably was happening before the upgrade and not being reported. Should the frequency of the warning increase then we will persue it more actively.
Funny you should say that. I don't recall that we had the error before Compaq came in and upgraded the array. However, we have another system which was also upgraded by Compaq and it doesn't report the error. At the most we only seem to get one message a day (often none), but it always seems to...
We have a Proliant 6500 with an HSG80 Storage Array running NT 4.0 Sp6a . We sometimes get the following warning reported in the System Log:
Event ID: 33
Source: hszdisk
Data was recovered using error correction code on device \Device\Harddisk0\Partition1
The warning is not reported for...
Evilbarts procedure can work, though on one of our servers after a similar upgrade pcAnywhere caused the server to reboot on exit. A better approach is to remove pcAnywhere before upgrade and re-install it afterwards.