When making an internal call between two lines, we notice that one of the parties does not hear the call, and sometimes the call is interrupted .
please help me .
Hello
It was noticed that communications were interrupted via E1 between two locations, and for your information, a detection of channels was made from SDH and it was working perfectly, knowing that there was an alarm in the PABX (E/W) on the electronic board (ADP). We hope that you will help me...
We have a problem connecting via E1 channels knowing I give it LCOSV1 = 2 We but no ring ( busy ) also noted this number NIGHT option feature reference
Please help us and thank you very much
I removed the card, cleaned it and rebooted again, but the problem still exists as shown in the attachmenthttps://files.engineering.com/getfile.aspx?folder=06629a45-08a5-4544-b701-8c781a014595&file=ahmed218.jpg
The same fonts have been applied, but the problem is still therehttps://files.engineering.com/getfile.aspx?folder=c8a9ce72-a18e-420b-8fbb-737c7d81c776&file=nnnaas.png
The same fonts have been applied, but the problem is still therehttps://files.engineering.com/getfile.aspx?folder=a3a745a8-3c6e-4bc6-b210-123605ad4dab&file=nnnaas.png
When viewing the license for the PBX via the dis-codew command, the attached message appearshttps://files.engineering.com/getfile.aspx?folder=4337e3e1-4a91-4cab-82c9-f657ef6e735e&file=itehad.png
When entering the system and displaying the information of any internal line, the attached message appears
https://files.engineering.com/getfile.aspx?folder=4da000cf-0217-4c8d-a5de-121782b79769&file=itehad22.png
peace upon you
we have a problem accessing the image , the atteched information shows a communication problem Via the DIUT2 board of the E1 .
thank you https://files.engineering.com/getfile.aspx?folder=41dc632f-8b89-4812-b850-b569cdcc0692&file=asasa545.png
Peace be upon you
We have a problem accessing the image, the attached information shows a communication problem via the DIUT2 board of the E1. Thank youhttps://files.engineering.com/getfile.aspx?folder=829ded57-0c85-46e7-9257-fdc947afd676&file=asasa545.png
Peace be upon you
We have a problem accessing the image, the attached information shows a communication problem via the DIUT2 board of the E1. Thank youhttps://files.engineering.com/getfile.aspx?folder=98a87572-b9e4-4185-863f-e10b8327189d&file=detected.png
Hi
What does the alarm mean or the lighting shown in the picture for Hipath4000v5? Thank you
https://files.engineering.com/getfile.aspx?folder=da91c1f3-ff8d-4390-ac0e-fdc895008bb9&file=????????_??????[1].jpg