Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. masviss

    x8 E&M setting

    Choose your option
  2. masviss

    Openstae 40 SIP cyrillic

    For basic SW versions 6.2.15 and older. You need to use the instructions.
  3. masviss

    HiPath 500 and BS4 connection

    It seems to me that you need to replace CMS with CMA. This is a recommendation from the documentation. And show us the pictures Settings - Cordless - System-wide and so on.
  4. masviss

    Configuring ROLMPHONE 400 on Hicom 300 E

    Please show reg-sbcsu:XXXX; new manager number. reg-sbcsu:YYYY; old manager number.
  5. masviss

    the configuration osbiz is not save on

    Try to save the database to the SD card via Assistant T, if I remember correctly, menu item 28-2-1. You will see the function value on the phone display.
  6. masviss

    HICOM 300H

    https://www.123.com
  7. masviss

    Hipath3800 Audiocode

    Probably, yes. Try to do it and see.
  8. masviss

    Hipath3800 Audiocode

    Hi! When programming ISDN, it is strictly necessary to install one master device and another slave device with the same protocol. Which side of the master is which slave doesn't matter. Usually the master is a PBX.
  9. masviss

    Hicom 300 E PBX Time Change

    Try the VT100 terminal.
  10. masviss

    Hipath 4000 v5 the SIP phone can not Transfer to other subscribers

    We have HP4000V4 and OS4000V7. We work with a MicroSip V3.21.3 softphone, the call transfer works as an attended transfer only. You need to make settings in the MicroSip. After that, the softphone works as a switchboard. See the settings in https://www.microsip.org/faq Q: How to do an...
  11. masviss

    connection E1 between X8 and Eco server 4000 V10

    Please do this ADD-COT:15,RCL&ANS&CEBC&TIE&CBBN&CBFN&PROV&LWNC&NLCR&TSCS&DFNN&NTON; CHA-TDCSU:PEN=1-1-12-0,COTNO=15; make a call from OSBiz to OS4k
  12. masviss

    connection E1 between X8 and Eco server 4000 V10

    Why there is no call when you dial the whole number is not clear to me. It's very difficult to play blind. To understand the problem, we need a trunk trace from the OS4K side.
  13. masviss

    connection E1 between X8 and Eco server 4000 V10

    ADD-KNDEF:1-1-110,OWN,,,,,EXT,,,,,EXT,,,,,,,; CHANGE-KNDEF:1-1-110,,,,,,,,,,,,,,Y,,,0;
  14. masviss

    connection E1 between X8 and Eco server 4000 V10

    ADD-KNDEF:1-1-XXX,OWN,,,,,EXT,,,,,EXT,,,,,,,; CHANGE-KNDEF:1-1-XXX,,,,,,,,,,,,,,Y,,,0;
  15. masviss

    connection E1 between X8 and Eco server 4000 V10

    This is an variant for testing.
  16. masviss

    connection E1 between X8 and Eco server 4000 V10

    I am so sorry. All claims to ATOS.
  17. masviss

    connection E1 between X8 and Eco server 4000 V10

    REST-BSSU:PEN,1,1,12; wait 15-20sec I do not know how DIUT2 will work. I have not tested this protocol on OS4k V10. PRI QSIG - ECMA this is the most correct connection option. Back to the ECMAV2 protocol CHA-TDCSU:PEN=1-1-12-0,PROTVAR=ECMAV2,SEGMENT=8,DEV=S2CONN,BCGR=1;
  18. masviss

    connection E1 between X8 and Eco server 4000 V10

    For X8 For OS4k CHA-TDCSU:PEN=1-1-12-0,PROTVAR=CORNV33,SEGMENT=1,DEV=S2CONN,BCGR=1;
  19. masviss

    connection E1 between X8 and Eco server 4000 V10

    I have not worked with OS4K in grace mode. I do not know what happens when working in grace period.

Part and Inventory Search

Back
Top