  1. brmryd

    How to check if ethernet cu (for connecting to digital expansion) works fine without the expansion

    Hi All, sorry got situation where my digital expansion hardware fault, & i'm wondering how i can make sure if the ethernet cu is working when i dont have any spare hardware digital expansion for test ? Tried to ask local partner they also dont have spare & i'd like to verify it before order the...
  2. brmryd

    Config password phone for users gone after random times

    Many thanks for the help - really appreciate it.
  3. brmryd

    Replace module analog (bp2) with module digital make other device in other module slot no tone

    Hi icet500, Do the the module digital hardware have a version compatibility i should aware of ? & when swapping module do the extension number in each port will be need to reconfigured ? Again many thanks for all your help
  4. brmryd

    Replace module analog (bp2) with module digital make other device in other module slot no tone

    Hi, the old one 1 module digital 8 port(bd3), recent installed in empty slot module combo (bd4: digital 6 + analog 4), and now i'd like to replace module 8 port module analog(bp2) with 8 port module digital(bd2). If let say i'd replace the module analog with module digital it still only 3...
  5. brmryd

    Config password phone for users gone after random times

    11 - & yes other site use 10 version never face issue like that. Is it due the version 11 ? Many thanks
  6. brmryd

    Config password phone for users gone after random times

    Hi, Need to ask another help if you dont mind, One of the avaya ip office on different sites have this kind of issue, suddenly the configuration for password just gone at random times (been twice already) and only the config for phone password, are there any config / logs / policy i can check...
  7. brmryd

    Replace module analog (bp2) with module digital make other device in other module slot no tone

    Hi, already did that, before i replace the module analog(bp2) with digital (bd2) i did these steps below: * login -> delete the module analog in control unit * delete the extension as well * save -> shutdown * replace it with digital * turn on back again still same - the devices digital phone...
  8. brmryd

    Replace module analog (bp2) with module digital make other device in other module slot no tone

    Hi All, Need to ask you something for below scenario: * In our control unit avaya ip office 500 currently from first purchased only have 2 modules: analog(bp2) & digital (bd3) * few weeks ago also installed another module digital in empty slot control unit (bd4) and it works fine * few days ago...