Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. miranpiscanc1

    Manager Provisioning restart

    Thank you. You are super user, but I always use mxone_admin Miran Piscanc http://www.mpcommunications.it
  2. miranpiscanc1

    Manager Provisioning restart

    Hi, I put the following command to restart the service /etc/init.d/eri_mp status /etc/init.d/eri_mp restart but it replies: NO SUCH FILE OR DIRECTORY how should I do to restart MP Thanks Miran Piscanc http://www.mpcommunications.it
  3. miranpiscanc1

    Mx-One Intrusion code

    Hello everyone. I need to be able to make an inclusion on a busy extension. What code do I have to do? The function is enabled in COS Thanks Miran Miran Piscanc http://www.mpcommunications.it
  4. miranpiscanc1

    MX-One Clock

    Hello everyone, what is the command to set the clock on MX-One Version 6.3 SP1 Thanks CATII non executed??!? Miran Piscanc http://www.mpcommunications.it
  5. miranpiscanc1

    intrusion tone on MX-One 6.3 SP1

    Yes, I have webserver ( softwareserver ) for upgrading telepfones. Miran Piscanc http://www.mpcommunications.it
  6. miranpiscanc1

    intrusion tone on MX-One 6.3 SP1

    Thanks for the reply. The phone in use is 6940. In the configuration I found the offending item, but if I put it at 0, after saving it back to 15 seconds. What am I doing wrong? I attach image...
  7. miranpiscanc1

    intrusion tone on MX-One 6.3 SP1

    Thanks for the reply. Maybe I'm misinterpreting the tone, because setting the 0, I no longer have the tone of the conference, and probably also the tone of inclusion. let me explain it better. I activated the call recorder with a third party using the CTI license. When the call is made and the...
  8. miranpiscanc1

    intrusion tone on MX-One 6.3 SP1

    Hello everyone, what is the command to deactivate the intrusion tone on MX-One 6.3 SP1 I tried to put parnum = 100, parval = 0 or 8 but the tone remains. Thank you Miran Piscanc http://www.mpcommunications.it
  9. miranpiscanc1

    Mitel 6940 IP

    Hello everyone. how can I get the phonebook from the IP phones on Mx-one SP6. The telephone directory means the telephone extensions. On the 32xx series digital telephones there is the button. I guess I have to code on IP phones. Thank you Miran Miran Piscanc http://www.mpcommunications.it
  10. miranpiscanc1

    CIL Output MX ONE

    Forgive my ignorance, I do not know very well MX-one. I have always worked on BP250. Currently on output 2 is already coming to the right string. callinfo_output_set -output 2 -lim 1 -type tcp -subtype asb501 -server 172.16.102.2 -port 5001 -format "[duration> = 1] [accesscode1 == 0]" -eol...
  11. miranpiscanc1

    CIL Output MX ONE

    Hi, who gives me a hand to configure the string coming out of the MX-One Version 5.0 sp4 so I see both outgoing calls, which incoming calls, missed calls. Thank you Now I have added the following: callinfo_output_set -output 2 -lim 1 -type tcp -subtype asb501 -server 172.16.102.2 -port 5001...
  12. miranpiscanc1

    Hide number for one shot outgoing call

    Thanks, I Have version 5.0 sp4 Miran Piscanc http://www.mpcommunications.it
  13. miranpiscanc1

    Hide number for one shot outgoing call

    Hello everyone, there is a code to obscure the outgoing number for a single call? Thanks Miran Miran Piscanc http://www.mpcommunications.it
  14. miranpiscanc1

    BP250 H323 TRUNK

    Thanks. I await possible verification. Miran Piscanc http://www.mpcommunications.it
  15. miranpiscanc1

    BP250 H323 TRUNK

    Thank you. I attach a few screenshots to show the programming of UCP, because I still can not run. BP sent directly from the extension number. . Miran Piscanc http://www.mpcommunications.it
  16. miranpiscanc1

    BP250 H323 TRUNK

    I add an indication: the BP makes the call as seen by the firewall, but the MFIM log does not know what to do, so it does not sound anything for privacy I masked some figures of public IP Miran Piscanc http://www.mpcommunications.it
  17. miranpiscanc1

    BP250 H323 TRUNK

    Thank you, on BP I made these settings, but do not know how to set the MFIM50? Miran Piscanc http://www.mpcommunications.it
  18. miranpiscanc1

    BP250 H323 TRUNK

    Perfect, the UCP100 is the evolution of MFIM50B. Just that I was looking for. How do I program the BP250 to connected via trunk h323 with MFIM50B? What settings have to follow? Thanks Miran Piscanc http://www.mpcommunications.it
  19. miranpiscanc1

    BP250 H323 TRUNK

    Hello everyone. Those who have already had occasion to set up a BP250 to be connected via H323 with another telephone exchange. To clarify, I need to connect a BP250 that has on board the IPU with UCP100 Ericsson / LG. Thank you all. Miran Piscanc http://www.mpcommunications.it
  20. miranpiscanc1

    BP250 error

    Hello, I found this error in the log. I do not understand the meaning AB: BATTERY BACKED UP RAM HANDLER ERROR Miran Piscanc http://www.mpcommunications.it

Part and Inventory Search

Back