You got it.......What confused me was the recall timer in the UM settings. I thought this must be a new addition compared to the seperate
The manual under the setting for the UM describes setting this timeout longer than the timeout for Intercept destinations at the pbx or the pbx...
Hi OBT,
As its an NS700 I'm using the in built UM.
I've already got FXD configured in the UM Config - System Parameters - Parameters for the operator transfer sequence, the extension transfer sequence and the alternate extension transfer sequence.
In the Dialling Parameters/MSW Notification...
Any help or assistance greatly received.
I've recently installed an Ns700 which had auto attendant option 1,1 pointed at ICD group 622.
After callers select this option and with queuing and busy both set to none, callers revert to the top level of aa and the menu repeating after just over a...
Cable used is Vencroft low burn, with 1mm conductors a foiled screen and tinned annealed copper CPC (Earth).
In the places where the most interference is caused, there appears to be 4 cables running parelell.
So we should be asking if ground tests have been done? The manafacturer (different...
Current network is cat6.
They are aware and have installed to the correct British standard. As such they are unwilling....They are using screened cable but I've never seen interference of this magnitude.
They say the screening on the cable is there to prevent induction into their circuit. In...
Hi,
Wondered if anyone can share an opinion on the following:-
My employers have recently had an alarm company install an addressable system inside a hotel.
We are having difficulty with the interference from the FP200 rated, screened cable that they have used to install their circuits.
I...
Of the top of my head, I thought that the 5 series were only compatible from v8 of the maintenance console.
When I was provided with the V8 software all of the relevant card upgrades came with it.
Its a physical card.
Legacy Gateway Cards KX-NS0132 Stacking Card for KX-TDE Series (STACK-S (TDE))
Its in the documentation for the NS1000 on page 7 of the installation manual for v3.2
Afternoon people,
I have a question regarding the setup of multiple ISDN30 circuits on the same switch. ie 2 x PRI30 cards
We will be installing a new NS700 system in the building in question but would like to know how this would have been configured in a KXTDA/NCP/NS system.
Our current...
Afternoon Gents,
I have an issue with a KXTDA200 and TVM200 and Group Voicemail
I have an auto attendant system with 6 options forwarding to various ICD Group eg
6605
6611
Im trying to re-record the greeting for the group mailbox by logging into VPS system with 500#6*6605#
I gain access to...
From maintenance console 4.1.4 Flexible Button, drop down the type until you get to system alarm on the extension you require.
From the Handset - Program - Flexible button to be assigned - 58 - Auto dial/Store - Program to exit
This system has already been programmed. This is how it was setup by the past "professional"
I can see what you meant though CWC3. I assigned each of the phantom extensions on a flexible button and now they ring as part of the DDI.
Thank you for your help, most kind.
Hi,
Im having a problem programming DDI's to extension numbers for certain DDI's.
We have three DDI's that are affected.
002 - 373 (373 is a phantom extension which rings at 208 and 209)
003 - 374 (374 is also a phantom extension which rings at 208 and 209)
013 - 208 - This rings direct at...
Thanks JRgood
I have the following so far, work are paying for all the tools and training to bring all telephony in house, over the next three years.
Test set with caller ID (display) - Purchased today http://uk.rs-online.com/web/p/telecom-test-equipment/7659602/
Tone generator and probe -...