Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. michelepin

    Cannot delete EL6 extension anymore !

    Thanks to all! I have contacted our support service, as suggested, because seems to be a severe data corruption. MP -- BLOG @ www.zerozone.it
  2. michelepin

    Cannot delete EL6 extension anymore !

    Hi all, i've already enquiry the forum but without any result. I'll try again. I'm managing a MD110 BC13 with 16 LIMs and i'm expecting faults since few weeks. Here's what happens: <EXTEE:DIR=2875;EXTEE:DIR=2875; SURE? (YES/NO) <YWAIT WAIT WAIT WAIT FAULT INTERRUPT MESSAGE FROM OPERATING...
  3. michelepin

    FAULT INTERRUPT

    HIMDP return me some errors: <HIMDP; DIAGNOSTICS FROM OPERATING SYSTEM TIME DATE 09:19:08 10OCT18 DIAGNOSTICS FROM LIM 001, LAST HIREI: 07:56:59 10OCT18 TIME DATE ERROR CODE 08:32:56 10OCT18 H'17 FAULTY INDEX LOGICAL PROGRAM ERROR ADDRESS = 02001620 ENTER SWSW B-LEVEL...
  4. michelepin

    FAULT INTERRUPT

    Hi all, i'm expecting strange behaviour of my BC13 MD110 system. When i did an EXTEE of any extensions, i got: <EXTEE:DIR=xxx; SURE? (YES/NO) <YWAIT WAIT WAIT WAIT FAULT INTERRUPT MESSAGE FROM OPERATING SYSTEM: RELOAD REQUESTED RELOAD REQUESTED SYSTEM INITIATED DATA < Sporadically i got...
  5. michelepin

    Removing a LIM from MD110 BC11 ecosystem... this is the right procedure ?

    Hi all, following some threads and the ALEX i try removing LIM 16 from out MD110 BC11 ecosystem with 16 LIMs. First, checking PU there: <CNPUP:LIM=16,CFUNC=YES; LOADED PROGRAM UNITS IN LIM LIM NUMBER 16 PU-NO PU-NAME PRODUCT NUMBER REV PATCH END then blocking LIM 16...
  6. michelepin

    MD11 alias for esternal destination

    Hi all, on an MD110 BC11SP13 i need to configure a short number (1555) that redirect to an external destination (geographic number). So, calls 1555 should be redirected to xxxx.xxxxxxx. Any hint how to do this ? Thanks, MP -- BLOG @ www.zerozone.it
  7. michelepin

    MD101 BC11SP13 - 101 FAULTY CLOCK PROCESSOR

    Thanks for your kidly help: LSU changed. But now i have some other faults and GJLSP got me a: EQU = 2-1-00-0 GS-MULT 0-3 GS SIDE 0 ACTIVE NOT ACTIVATED NOT SIGNALLING NO CLOCK CONTROL SIDE 0 ALARM 0010 0000 0000 0001 GSMINPUT 11111110 ERROR RATE LIM TO GS...
  8. michelepin

    [SOLVED] DID on external destination

    Just for future reference, i add relevant entries on NUMBER CONVERSION DATA table with NUTRI; -- BLOG @ www.zerozone.it
  9. michelepin

    [SOLVED] DID on external destination

    Hi all, on a BC11SP13 i have some external destination connected to a VoIP system through ISDN trunk. DID was 4 digits for all. When internal calls occours, all works fine *but* when there are incoming calls to some external destinations, DID was sent fully and not "chopped to last 4 digits...
  10. michelepin

    MD101 BC11SP13 - 101 FAULTY CLOCK PROCESSOR

    Hi all, this morning i got a class 4 error: CLASS: 4 101 FAULTY CLOCK PROCESSOR DATE TIME ALP NOIF EQU INF1 26FEB18 12:10:20 1 1 002-0-**-** 1 following Alex, i checl LSU and then i want to the PBX to check LSU board. The only spare part i have is a R11...
  11. michelepin

    [SOLVED] Change EXT on a Digital Ext with ADN

    Thanks, i think i've solved with: KSANE:ADN=11190; KSDNC:DIR=3490,DIROLD=2290; SUDIP:DIR=3490 KSANI:DIR=3490,KEY=23,CAT=5,ADN=11190; SUDIP:DIR=3490; SUDIP:DIR=11190; -- BLOG @ www.zerozone.it
  12. michelepin

    [SOLVED] Change EXT on a Digital Ext with ADN

    Hi all, i need to change number (at the moment is 2290) to the following phone: <SUDIP:DIR=2290;DIRECTORY INFORMATION AT 10:42:29 15DEC17 DIRECTORY NUMBER : 2290 TYPE OF DIRECTORY NUMBER : DTS EXTENSION TERMINAL DATA EQU TERMD ADN CALALT 2-1-62-14 0021 1...
  13. michelepin

    ERROR DURING DUMPING OF CIL DATA

    After further checks, while trying to get CDR via FTP, i got: * Connected to xxxxx port 21 (#0) < 220 172.16.41.187 pSOSystem FTP server (NTL68K/1.0.4) ready. > USER xxxx < 331 Password required for xxxx > PASS xx < 230 User xxx logged in. > PWD < 550 4.0/ > PASV * Connect data stream passively...
  14. michelepin

    102 POWER FAILURE DETECTED BY DSU

    Thanks for your kindly help. But i've not REU nor RG5DC in this lim. Maybe the PU4DC ? And can i replace the PUA4DC with a RG5DC ? Michele -- BLOG @ www.zerozone.it
  15. michelepin

    102 POWER FAILURE DETECTED BY DSU

    Hi all, i've got this error on my MD110 BC11 REL 13: CLASS: 4 102 POWER FAILURE DETECTED BY DSU DATE TIME ALP NOIF EQU INF1 INF2 25AUG17 08:31:45 1 1 005-0-**-** 0 4 Looking on further posts, i've tried removing all TLU29 boards *but* alarm still there...
  16. michelepin

    ERROR DURING DUMPING OF CIL DATA

    <EDFIP; FILE ADMINISTRATION FILE STATE DEV DEVICE STATE PRIO SMDR ACT SI-0 SIU SYSTEM BLOCKED C END < -- BLOG @ www.zerozone.it
  17. michelepin

    ERROR DURING DUMPING OF CIL DATA

    Hi all, i got this errors from my BC11 SP13: CLASS: 3 75 ERROR DURING DUMPING OF CIL DATA DATE TIME ALP NOIF UNIT EQU BRDID INF1 INF2 INF3 24AUG17 10:35:35 2 1 SIP 002-2-63-00 29 2 3 1 278 CIL DATA LOST FOR ONE OR MORE OUTPUT UNITS...
  18. michelepin

    SOFT PARITY ERROR IN LIM PROCESSOR MEMORY

    Thanks for your prompt reply. Following flow diagram, seems to be nothing dangerous. So, i clear errors log and waiting for another (hoping no) error. Luckly, there's no ext linked to that LIM. Michele -- BLOG @ www.zerozone.it
  19. michelepin

    SOFT PARITY ERROR IN LIM PROCESSOR MEMORY

    Ok, googling around i followed this procedure: http://www.pdn.ac.lk/doc/alex/20_15451-CNA103255Uen.C1.html and i got: <HIMDP; DIAGNOSTICS FROM OPERATING SYSTEM TIME DATE 09:37:03 06MAR17 NO INFORMATION STORED IN LIM 001, LAST HIREI: 12:52:46 22FEB17 NO INFORMATION STORED IN LIM 002...
  20. michelepin

    SOFT PARITY ERROR IN LIM PROCESSOR MEMORY

    Hi all, in my MD110 BC11 system i got a 111 SOFT PARITY ERROR IN LIM PROCESSOR MEMORY. DATE TIME ALP NOIF UNIT EQU INF1 INF2 03MAR17 11:54:17 3 1 RMP 003-0-**-** 0 0 RDATE RTIME 03MAR17 11:54:17 What it means ? And what i can do ...