Trying to order replacement memory modules for a HiPath 4000 V6. Having trouble identifying the correct type. Any help is greatly appreciated. Thanks in advance.
Mark
Thanks, all. Looks like I'l be going with a small switch connected to eth0. What I find most frustrating is that in all of my documentation, it clearly states that these ports are 'freely assignable', but I can find nothing that gives me a clue as to how. I can't use a PC for the NTP source...
Yeah, I thought of that and may try tomorrow. Just bothered that I can't seem to use the existing ports for anything. Why are they there? Thanks again.
Also forgot to mention that this switch is in my shop, so not actively deployed. It's why we have it, so we can experiment without consequences. Thanks for the replies.
Unusual installation, where the HiPath is not connected to ANY network. Truly isolated, to the point the only access is with a laptop plugged into eth0 (Customer LAN). If I connect the laptop to any of the other ports (except the Atlantic LAN ports), I am unable to access the switch. I am trying...
The ComWin tool defined ports 2 thru 7 with IP address of 0.0.0.0 and any attempt to change has been unsuccessful. Actually shuts down the Portal. Frustrated, so maybe I'll let it rest until tomorrow. Thanks for the reply.
Good morning. Having trouble adding a NTP server to a HiPath 4000 V6. If I connect the server to ETH0, all is well, but if I connect to any of the other ports (ETH2) for example, the server is not found. I would like to keep ETH0 available for access via my laptop and really want to connect the...
I have assigned a DSS key on an Optiset so that there is an appearance for an analog extension, but I want the Optiset to ring when the analog extension is called. Checking the 'Ring Option' button has no effect. What am I missing?
Thanks for the replies, all. Unfortunately, any kind of internet connection is not allowed on this equipment. It has to remain isolated. $800 is not a bad solution on it's own, but times 15 sites is likely to raise a few eyebrows. There is some new equipment getting installed starting this...
A little clarification. When I said 'Remote', I meant 'isolated'. These are standalone installations with no connection to the outside world beyond the inbound trunks. No NTP server, no 'main site', no administrative access. I have to travel to the site via AF or charter aircraft for any...
I have 15 HiPath 4KV6 switches located at remote sites around the State of Alaska. They are installed at USAF stations that are run entirely on generator power and the time display on the OpenStage phones is never correct, nor is likely to EVER be! Is there a way to turn the display off?
HiPath 4000 V5, how can I get an analog phone to ring simultaneously with an OpenStage40? The OpenStage is located in a very noisy area and I want to ring an external bell when the number is called. Thanks in advance.