Yeah, I have the 800 number and I know what numbers are available in the switches. Just not sure how to get the three digits to dial/route or forward to the 800#.
Hi all,
What would be the best way of adding a three digits code to dial a toll free number in a 81c RELEASE 4?
We have been task to add the toll free suicide hotline of 988 in the three 81c switches we have here.
Couldn't use 98 because 98 is used for something else. Looking to use 966. Any and...
Hi all,
What would be the best way of adding a three digits code to dial a toll free number in a 81c RELEASE 4?
We have been task to add the toll free suicide hotline of 988 in the three 81c switches we have here.
Couldn't use 98 because 98 is used for something else. Looking to use 966. Any...
Would anyone know if there is a way of setting up a feature code in the 81C switches ( version 3621 rel. 4) to temporarily remove battery on a POTS line in order to test the line/dry line? In the SL100 its called silent switchman and is used by entering a three digit code. Thanks.
And to elaborate on this for those that may read it. I have replaced release 9s that have gone bad. Was told by a senior Tech Support engineer that releases 6-9 were having early life failure and that when replacing one 13 or higher should be used.
Thanks for the reply. I have replaced several already and was in the need of spares. Several more are still working. I ask for 14 or higher and what was sent were release 7s and 9s. Thats what I have working now and are subject to being replaced. Thought if I had the bulletin, if there was one I...
Was wondering if anyone was familiar with the Nortel bullentins that were put out about the release numbers of the NT6x40ga DS512 Link Paddle Board cards? We have several that have been replaced and was told the release had to be 14 or above. Anyone that could be of help, I would appreciate...
Ok, went ahead and did it inspite of what I've always heard about the switches resetting itself when doing anything in the core cabinets.
SWCK in ld 60.....ok
Checked to make sure it switched
DIS CC 0 in ld 60......ok
SEFT CC 0 in ld 60.......selftest passed
Cleared the NO UART.....Now No...
Having an issue with one of our 81C clock controllers. It seems the active clock isn't seeing the inactive clock causing a DTC010. Posted below.
ssck 0 full
ENBL
CLOCK ACTIVE
GROUP 1
SIDE 0
CLOCK CONTROLLER - LOCKED TO LOOP 22
PREF - 22
SREF - 51
AUTO SWREF CLK - ENBL
NO UART
CARDID...
For those who may someday need something related to what I've tried to find out here.
Did a stare and compare with a 81c that was also working through our voicemail.
What was changed in LD 16 RDB in order to make it work was the following: I changed them all at once so (may not need all of them...
I have also tried to change CNUD and CNAD but was denied with a SCH1885. The switch is tied to an SL100 through commercial T1's. It looks like all are setup the same so I've only posted one below;
TN 002 01
TYPE DID
CDEN SD
CUST 0
TRK PRI
PDCA 1
PCML MU
NCOS 0
RTMB 2 1
B-CHANNEL...
We have an 11c
CALL SERVER/MAIN CAB
VERSION 2121
RELEASE 4
ISSUE 50 W +
IDLE_SET_DISPLAY NORTEL
that we need to get on our Callegra voicemail system. I have managed to get the call forwarding out of the switch by changing CFO to CFF in the CDB. It will forward to the Callegra but doesn't...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.