if you buy vmibe card you can record calls by pressing button. bossman must have digital keyset with button programmed. however you can not get file off card to email etc
there was also a daughter board with usb lead that fitted to 16/24 button keyset that plugged into pc and you could record calls from that station to pc
important second cabinet starts before main cabinet. best solution is to use battery back up not ups. just use 2 x 12 volt batteries wired to give 24 volt and connect.