ok,
i will try to make all macro calls to 1 at workplace in morning.
Code is being generated through our own libraries. Generator (the actual pcl writer) is what i am playing with.
yes,it has to be sent to a color printer and can be sent to a black printer.
Attached analysis contains 24bit images.
Macros just contain Raster Data and required commands related to image(including pallete,width,height,config image data,start & end raster data).
You may search the attached...
Hi,
Attached is the PCL Paraphernalia Analysis of the stream.
We have 5 images in total placed on 40 different pages. Raster data is placed separately in 5 macros for each image.
Image appears on first page while printing but other 39 pages are blank.
Escapee & PCL works previews are fine...
k, i will have a try.
and what would you think be the preferered approach to minimize pcl stream size in case of many images. Just compression or any ideas?
>>Perhaps use 'arbitrary' Raster Scaling in conjunction with a macro storing the 'base' raster image?
>>It requires use of the 'Configure Image Data', 'Destination Raster Width' and 'Destination Raster Height' sequences.
ok,
could you plz elaborate these terms.
i have not seen any thing like...
This is the scenario:
I get some images first then the details where these images are to be placed. Detail contain there position on those pages with sizes.
Will it be possible to construct the PCL image once and place it on different pages with required sizes?
Currently images are placed...
Hi,
I want to reuse a PCL raster image that is defined once in stream and required to placed with different scales on multiple pages.
If any other work around is possible for reusing the same image for different sizes(resolution).
Kindly reply.
and what if we are developing our own PCL XL writer, then should we write these already encoded hexs or XL commands in ASCII?
for e.g.
ubyte eInch Measure
or
0xc0
0x00
0xf886
Hi,
I am in the process of converting a PCLETTO to TTF.
I have the following data in hand fom PCLETTO:
head Font header (in PCL GT segment)
hhea Horizontal header (in PCL GT segment)
hmtx Horizontal metrics (in PCL GT segment)
maxp Maximum profile (in PCL GT segment
cvt Control Value...