Hi Wonnag
I've ever recieved advise from Aastra when installing MP on multi LIM system, it is best not to install MP on LIM 1 as LIM 1 already has the highest load. You can install it on any other LIM, such as LIM 2. I've never had a 22 LIM system before though.
Best regards
Hi it is possible.
Using command KSMDI, you can set another extension to monitor this extension and pick up the calls.
KSMDI:dir=yyy,mdn=xxx,dig=xxx,key=??;
DIR: another phone to pickup user1 phone
MDN and DIG is the extension to be monitored. (User1)
key: any unused key on your digital...
Hi all
I am using TSE and i am trying to get the clock timing from a NTP server.
I have set in yast the NTP server but the TSE is still getting timing from the local clock. Any idea how to get the PBX to get the timing from the NTP server?
Many Thanks
Hi all
I am using TSE 4.1 SP4.
I have 2 ACD grp and i want 2 different MOH to be played for the 2 ACD grp. I understand that i need to connect the TMU to the CD Player.
What programming needs to be done so that i can assign the correct MOH to the correct ACD grp?
I've done abit of research...
Hi i have tried many attempts to mount DVD in VMware SUSE with no success. The procedures are as follow
In VSphere Client,
select the VM for SUSE server --> connect CD/DVD drives --> Connect to F;
Then in SUSE, i enter command : mount /dev/cdrom /mnt/dvd
It always throws a message ...
Hi all
I forgot about this problem awhile ago as i just used upgrade the MGU directly using a USB stick. I found out the problem for my above error.
For anyone facing this problem, i log in as root then into mdsh shell when typing the command for upgrade.
It returns "server not found"...
Hi
I am using ethernet bonding redundancy for my network.
Regarding the MGU, i have to set eth0-3.
There is a command in alex that says:
media_gateway_interface -mgw -redundancy
Must the above command be executed to enable the MGU link fail over?
Many thanks
Hi all,
I have a 7434IP which is able of SIP and H323.
When i change from H323 to SIP protocol, the time display is wrong.
Using H323 protocol it shows the correct time.
Anyone has similar experience?
Hi all
I'm trying to upgrade the MGU with the latest package, but there seems to be some error. I've copied the MGU rpm into the TS directory:
opt/jboss/server/default/deploy/jboss-web.deployer/ROOT.war/mgu/1.3.134
Then key in the command:
board_sw -gateway -netload -path mgu/1.3.134...
Thanks for the reply
The eri_heartbeat pings all other server in the cluster every other sec. That means that the standby server will take over the failing server immediately if any active server fail.
However, for the standby server to be able to start functioning, the time taken is = to the...
Hi
Just an update, i read in the documentation that the "heartbeat"
service ping all the server every sec. So i assume that the standby server will take over the failing server immediately?
Many thanks
Hi all
I am doing a testing on caller ID from analog trunk.
I have an analog trunk from PSTN connected to a analog phone. The caller ID works.
However, when i connect the analog trunk to TLU-83 and makes a call using the DDI number, and divert it to a digital extension using "RODNI day=100"...